5
OAP manager timers
The OAP manager uses the following timers:
•
Clock synchronization timer
—Regularly triggers the OAP manager to send clock and time
zone synchronization notifications to OAP clients. This mechanism keeps the clients' clocks
synchronized with the manager's clock.
•
Client monitoring timer
—Regularly triggers the OAP manager to send client monitoring
packets to OAP clients.
Configuring the OAP manager
Enabling OAP
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter interface view.
interface interface-type
interface-number
N/A
3.
Enable OAP.
oap enable
By default, OAP is disabled on an
interface.
Setting the clock synchronization timer
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Set the clock synchronization
timer.
oap timer clock-sync
minutes
By default, the clock
synchronization timer is set to 5
minutes.
Setting the client monitoring timer
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Set the client monitoring timer.
oap timer monitor seconds
By default, the client monitoring
timer is set to 5 seconds.
Managing OAP clients
You can restart or shut down an OAP client.
Restarting an OAP client
Step Command
1.
Enter system view.
system-view