background image

<?

xml

 

version

=

"

1.0

"

 

encoding

=

"

utf-8

"

?> 

<

Measure

 

serial

=

"

1111000002

"

 

dc

=

"

1

"

 

battery

=

"

1.2

"

<

Info

 

servertime

=

"

20111221132941

gwtime

=

"

20111221132941

"

 

sim

="310260760561444

fw

="H3G-700 v1.0.28"

 

signal

="99,99"

 

/>           

<

Device

 

type

=

"

Pressure_AND

"

        <

Data

 

id

=

"

5080600120

"

 

measuretime

=

"

20111109132941

"

 

sys

=

"

155

"

 

dia

=

"

98

"

 

pul

=

"

77

"

 

battery

=

"

2.63

"

   

con_gwtime

=

"

20111221132941

con_devtime

=

"

20111221132941

"

 /> 

    </

Device

    <

Device

 

type

=

"

Weight

"

        <

Data

 

id

=

"

2222222201

"

 

measuretime

=

"

20110901142303

"

 

result

=

"

068.60

"

 

unit

=

"

kg

"

 

battery

=

"

2.3

"

 

 

con_gwtime

=

"

20111221132941

con_devtime

=

"

20111221132941

"

 /> 

    </

Device

    <

Device

 

type

=

"

Glucose

"

>             

        <

Data

 

id

=

"

ZHZ3064BY

"

 

measuretime

=

"

20111109142303

"

 

result

=

"

463

"

 

unit

=

"

0

"

 

model

=

"

1

"

 

adapter

=

"1"

 

 

con_gwtime

=

"

20111221132941

con_devtime

=

""

 />   

</

Device

<

Device

 

type

=

"

Glucose

"

>             

<

Data

 

id

=

"

ZHZ3064BY

"

 

measuretime

=

"

20111109142303

"

 

result

=

"

463

"

 

unit

=

"

0

"

 

model

=

"

1

"

 

adapter

=

"

2

"

 

battery

=

"

3.0

"

 con_gwtime

=

"

20111221132941

con_devtime

=

""

 />                           

</

Device

<

Device

 

type

=

"

Thermometer

"

        <

Data

 

id

=

"

00123E0019B5

"

 

measuretime

=

"

20100101001000

"

 

otemp

=

"

97.88

"

 

btemp

=

"

83.66

"

 

unit

=

"

F

"

 /> 

    </

Device

    <

Device

 

type

=

"

Pressure_IEM

"

        <

Data

 

id

=

"

61102DM2

"

 

measuretime

=

"

20110215151641

"

 

sys

=

"

157

"

 

dia

=

"

100

"

 

pul

=

"

091

"

   

con_gwtime

=

"

20111221132941

con_devtime

=

"

20111221132941

"

 /> 

    </

Device

    <

Device

 

type

=

"

OXI

"

>                     

        <

Data

 

id

=

"

0018E41E7B7F

"

 

measuretime

=

"

20100116012117

"

 

pid

=

"

001

"

 

temp

=

"

000

"

 

pr

=

"

075

"

 

spo2

=

"

90

"

   

battery

=

"

10

"

 con_gwtime

=

"

20111221132941

con_devtime

=

""

 />                                                         

</

Device

<

Device

 

type

=

"

OXI

"

>                     

        <

Data

 

id

=

"

0018E41E7B7F

"

 

measuretime

=

"

20100116012117

"

 

pid

=

"

001

"

 

temp

=

"

000

"

 

pr

=

"

075

"

 

spo2

=

"

90

"

 

battery

=

"

10

"

/>                               

    </

Device

</

Measure

>

 

 
 

Содержание H3G-900

Страница 1: ...LTE tele health modem Instruction H3G 900 H3 System Co Ltd ...

Страница 2: ... Revision Notes No Date Version Content Author 1 2017 3 21 0 1 ...

Страница 3: ...l interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by tuning the equipment off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient or relocate the re...

Страница 4: ...components This document includes How to install and configure the H3 LTE tele health modem How to use the H3 LTE tele health modem How to setup a server system for the H3 LTE tele health modems 1 Specification Item Specification MCU STM32F207VC 32bit Cortex M3 MEMORY Internal FLASH 256KB External FLASH 1MB SRAM 128KB RF Transceiver 15C Freq Range 2402 0 2480 0 MHz POWER 0 343mW MHz Typ Class2 Fre...

Страница 5: ...ure 1 ii Connect a serial cable provided by H3 System to a LTE tele health modem and a PC iii Run the configuration software iv Turn on the LTE tele health modem v Configure the LTE tele health modem with the configuration software For the details please see the section below LTE tele health modem configuration B Pairing and testing i Pair with devices Please see Pairing section below Figure 2 ii ...

Страница 6: ...Figure 1 Power ON Switch Figure 2 FW Download Console mode Selection 1 Booting left 3 Download right ...

Страница 7: ...cked for changing LTE tele health modem configurations iii Serial No Serial number of the LTE tele health modem It s only enabled for the Admin version iv IP DNS DataCollection Server IP or DNS v Port DataCollection Server port vi Devices List List of paired devices Types and BT addresses vii Delete List CheckBox save GWInfo delete Pair info Delete Saved Flash Data viii if Setting Checkbox Check a...

Страница 8: ...he suitable COM port You can check the COM port at the device manager and click Open E If you want to modify configuration then check Setting Otherwise uncheck Setting F Turn on the LTE tele health modem G The current configuration and paired devices info are shown H Change the parameters and click Send I If you want to delete the pairing info check Delete List and click Send J Before clicking Sen...

Страница 9: ...ice List listbox will add pair info xi At failure the Readings LED blinks RED 5 times xii The LTE tele health modem goes to the step v xiii You can pair another device at the same pairing mode successively xiv After completion of pairing UnCheck AdminUI Setting CheckBox LTE tele health modem will normal operation xv For failure just let the device at pairing mode and find the result Step vii and v...

Страница 10: ...W automatically updates the pairing results into AMC s DB through DC SW 6 AMC checks whether the process is successfully completed through AMC s DB 7 If register several BT device AMC has to guide Patient set BT device in pairing mode sequentially C Final 1 AMC can find out all BT device pairing is completed via DB info 2 AMC confirms whether the Bluetooth device is functioning properly ...

Страница 11: ...re monitor clock must be set manually 3 LED indications A During Bluetooth communication the Readings LED turns GREEN B At success the Readings LED blinks GREEN 5 times C At failure the Readings LED blinks RED 5 times D During server connections the Sending LED turns GREEN E At success the Sending LED blinks GREEN 5 times F At failure the Sending LED blinks RED 5 times 4 Notification for power fai...

Страница 12: ...vice ii Change the configuration file gprs_config ini iii Re start the windows service E To start the windows service At Windows Service select DataCollection_GPRS and run 2 Data files and communication log files A Data XML files will be generated at the folder defined at DATA_PATH B Log files will be generated at the folder defined at LOG_PATH C Examples Ex Data XML file name H3_20101004194422_11...

Страница 13: ...sult 463 unit 0 model 1 adapter 1 con_gwtime 20111221132941 con_devtime Device Device type Glucose Data id ZHZ3064BY measuretime 20111109142303 result 463 unit 0 model 1 adapter 2 battery 3 0 con_gwtime 20111221132941 con_devtime Device Device type Thermometer Data id 00123E0019B5 measuretime 20100101001000 otemp 97 88 btemp 83 66 unit F Device Device type Pressure_IEM Data id 61102DM2 measuretime...

Страница 14: ...between the measuring device and LTE tele health modem If the measuring device supports sending device s current time Glucometer result 103 Measurement value unit 0 Unit 0 mg dL 1 mmol L model 1 Glucometer Model 0 Ultra 1 Ultra2 2 Mini Easy adapter 1 Glucometer Adapter 0 N A 1 BA 100 2 BA 110 battery 3 0 Battery level only for BA 110 BP Monitor AND sys 139 Systolic dia 091 Diastolic pul 094 Pulse ...

Страница 15: ... servertime timestamp of DataCollection Server during communication between LTE tele health modem and server gwtime timestamp of LTE tele health modem during communication between LTE tele health modem and server sim SIM card ID including carrier info fw LTE tele health modem firmware version signal signal strength format signal rssi ber ...

Отзывы: