v.
Port: DataCollection Server port
vi.
Devices List: List of paired devices. Types and BT addresses.
vii.
Delete List: Delete all pairing info.
viii.
Clear Button: Clear window
ix.
Send Button: Send a new configuration to the gateway
x.
3G Log: 3G AT-command logs
3)
Steps
A.
Turn off the gateway.
B.
Connect a serial cable (provided by H3 System) to a gateway and a PC.
C.
Run the configuration software.
D.
Select the suitable COM port (You can check the COM port at the device manager.)
and click “Open.”
E.
If you want to modify configuration, then check “Setting.” Otherwise uncheck
“Setting.”
F.
Turn on the gateway.
G.
The current configuration and paired devices info are shown.
H.
Change the parameters and click “Send.”
I.
If you want to delete the pairing info, check “Delete List” and click “Send.”
J.
Before clicking “Send”, please double check the settings.
K.
Turn off the gateway and disconnect the serial cable.
9. Pairing
1)
Mode selection switch
A.
“N”: Normal operation mode