background image

FlowVis

®

FlowVis

®

Flow Meter 

- Metric Models

English

Rev.4.5.1M

Operating Manual

DN40/50/80/100 models

DESCRIPTION

FlowVis® is a revolutionary, patented solution for accurate and 

reliable flow rate measurement in fresh water applications 

such as swimming pools, spas, fountains, water features, 

irrigation systems, well water and solar systems.

Using a design that is based on ‘mass flow’ principles, the 

FlowVis® provides many benefits that include:

•  Ease of installation without the need to have 15x of 

straight pipe

•  Installation flexibility that allows orientation in any 

position, e.g., horizontal, vertical or even upside-down

•  Long life without sticking floats or paddle wheels
•  Combined Flow Meter and Check Valve for DN40 and 

DN50/65.

CONCEPT

As flow increases, the flapper moves forward toward its 

fully open position. The flapper’s angular position is directly 

related to flow rate through the valve body / tee. A calibrated 

scale on the valve’s lid provides a highly accurate reading of 

the flow rate.

Calibrated Scale

Flow

www.h2flow.net  

  Tel:  (+1) 419-841-7774  

• 

www.drydenaqua.com

IMPORTANT NOTE:

 For the most up-to-date version of this manual, please visit www.h2flow.net/product-literature

SERVICE REPAIR KIT

A service repair kit is available for all models:

- DN 40 and DN 50/65 (Art.Nr. 90024)

- DN 80 and DN 100 (Art.Nr. 90025)
The repair kit comprises:

•  1 x o-ring
•  1 x spring
•  1 x flapper and indicator arm (only 90024)
•  1 x pivot pin

For all other parts, please contact H2flow at (+1) 419-

841-7774 (International).

Содержание FlowVis DN100

Страница 1: ...g floats or paddle wheels Combined Flow Meter and Check Valve for DN40 and DN50 65 CONCEPT As flow increases the flapper moves forward toward its fully open position The flapper s angular position is directly related to flow rate through the valve body tee A calibrated scale on the valve s lid provides a highly accurate reading of the flow rate Calibrated Scale Flow www h2flow net Tel 1 419 841 77...

Страница 2: ...When selecting a physical location to install FlowVis be sure to allow accessibility to read the scale on the lid Pay particular attention to the system s direction of flow and make sure that the arrow on the lid of the FlowVis is pointing in the correct direction For the DN80 and DN100 versions the Tee will have an additional arrow on one of its bosses In the event that the FlowVis is inadvertent...

Страница 3: ...hlorine Feeders damaging other equipment such as Heaters www h2flow net Tel 1 419 841 7774 www drydenaqua com Installation Tightening Lid Screws 3 TIGHTENING LID SCREWS When removing and re installing the FlowVis lid assembly it is important to adhere to the following procedure 1 Make sure that the o ring on the underside of the lid is undamaged lubricated with silicone such as Boss 820 and is in ...

Страница 4: ...d near the rear of the lid 2 Indicator arm is being viewed correctly 3 Indicator arm is being viewed too far back front of the lid MAINTENANCE Although FlowVis is designed to be maintenance free periodic checks should be made to the following Condition Check for Remedy Leak around lid seal O Ring Failure Replace O Ring Leak from lid Cracks in lid Order new lid from supplier Higher flow reading tha...

Страница 5: ...0 08 0 10 0 12 0 14 0 16 5 7 9 11 13 15 17 19 21 23 25 Head Loss Bar FlowRate m3 h Head Loss Bar DN50 Head Loss DN50 0 000 0 005 0 010 0 015 0 020 0 025 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 Head Loss Bar FlowRate m3 h FlowVis HeadLoss Bar DN80 Head Loss DN80 0 004 0 006 0 008 0 010 0 012 0 014 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 Head Loss Bar FlowRate m3 h FlowVis H...

Страница 6: ...DN40 and DN50 65 Viton Lower Flapper DN80 and DN100 only ABS Interconnecting link DN80 and DN100 only 316 Stainless Steel Lower Retaining Pins DN80 and DN100 only 316 Stainless Steel Materials used Function Models Comments Max working pressure All models 3 5 Bar Accuracy FV C M DN40 and FV C M DN50 65 Average 97 9 98 97 5 Accuracy FV M DN80 and FV M DN100 Average 98 6 in straight pipe Min Max oper...

Отзывы: