H-ITT RX4000 Скачать руководство пользователя страница 1

 

H-ITT RX4000 instruction manual 

H-ITT      420 Shearer Blvd     Cocoa, Florida     32922 

 

GENERAL:  

The RX4000 communicates with all H-ITT RF clickers. There is no limit to the number of RF clickers that can be used with the RX4000. 
The RX4000 has 31 RF channels that can be selected and are provided so that a classroom may have a unique RF channel to avoid 
interference between another device in or about the classroom. The RX4000 is initially set to channel 07 to operate with H-ITT RF 
clickers that are also initially set to channel 07. The RX4000 has selectable baud rates for communication to your PC. The default 
setting is 19.2K baud. Higher Baud rates are available, but typically not needed. If higher baud rates are selected, the length of the USB 
cable should not exceed 15 feet. There can be more than one RX4000 installed in a very large classroom or auditorium to provide 
reliable communication with H-ITT’s remote clickers.  

 

INITIAL SET-UP:  

The RX4000 provides both USB and Serial communications ports. 
Connect either of these ports to your classroom PC (do not connect both). 
The 

USB connection

 provides power to the unit, so this is the only 

connection needed. You will need to install a driver for the USB port in 
your PC to communicate with H-ITT software (see below for connecting to 
a computer). However, the RX4000 will power up as indicated below with 
or without the drivers installed.  
Attach the antenna to the SMA connector. 
Power up the RX4000 by connecting the USB cable to a PC (that is 
powered up) or connect the external power supply to the DC power jack. 
The YELLOW indicator light will turn on and both the GREEN PC com and 
RED RF com indicators will blink 4 times each. If the RF com indicator 
blinks more than 4 times, and at a rapid rate, this can indicate that the RF 
channel selected may have another fixed frequency transmitter operating on the same channel within the range of the base. If this 
occurs, it is recommended that a different channel be selected using the internal set-up switch described below.  

 

Connecting the RX4000 to your computer:

 

You can connect the RX4000 to your computer using the USB cable (which also provides power to the RX4000) or through a serial 
connection (which requires an external power supply). The most common is the USB connection with the cable provided. Depending on 
your operating system (Windows, Mac or Linux) you may need to install USB drivers for the software to properly handle the 
communications from the RX4000 to your computer. USB drivers vary depending on your computers operating system; Windows or 
Mac (Linux drivers are built in). Windows and Mac USB drivers are included on the CD supplied with the RX4000, click the link to 
download/install the appropriate USB driver for your operating system. USB drivers are also provided at H-ITT.COM from the download 
links where you will find instructions based on your operating system.   

Installing Windows USB drivers

 may be confusing because when the RX4000 is first connected a “found new hardware” wizard will 

pop-up. If you are connected to the Internet, this wizard can locate and install the proper drivers, but if not connected to the net the 
wizard will return “drivers not found”. To simplify this, we recommend that you download the Windows USB driver “auto installer” to your 
computer (either from the CD or from H-ITT.COM) and install drivers by double clicking the “auto installer”.exe file. 

If the 

Serial port

 is used, the unit must have an external power supply connected, use H-ITT part number # AC-9VDC-US for standard 

North American power outlets or AC-9VDC-INT for international power outlets. 

 

TEST

  

With the RX4000 powered up, 

the RX4000 using a H-ITT RF remote (TX3000 or TX3100)

 

by pressing a button (A/1 through J/0) 

on an RF clicker and notice the GREEN PC Com light and RED RF com lights blink. This indicates the RX4000 is ready to operate. 

Test with H-ITT software

 to make sure USB drivers are installed and the RX4000 is communicating with your computer: 

Open H-ITT-CRS Acquisition program. On the initial screen of the Acquisition program under “Base Units and Port Settings” you will 
see a new COM port appear when the base unit is connected with a USB cable. When a remote is activated, the remotes serial number 
will appear under the Detected Responses columns. 

Test the RX4000 installation: 

To ensure reliable communication between the RX4000 and remotes, go to the far corners of the 

room (or from worst case seat positions) and verify the remotes green light turns on with a key press, and The RED and GREEN lights 
on the RX4000 blink with each key press. 

 

 

In most applications your H-ITT system is now ready to operate using the default settings, so once you verify that the RX4000 powers 
up , and communicates with software, it is ready to use.  

The following options of the RX4000 can be used if the application requires, but typically is not necessary.

 

USB Port 

Serial Port 

DC power jack 

Power indicator 

Antenna 

PC com indicator 

RF com indicator 

Rev 1.0 

Отзывы: