Solenoid Pump Instructions

Safety Considerations

All pumps are tested for correct operation with 
water before shipment. When pumping solutions 
that are not compatible with water, disassemble 
the pump liquid end and dry all parts thoroughly 
before use. The pump liquid end includes the 
pump head, diaphragm, suction valve, discharge 
valve and seals.

Warning: Use extreme caution and 
use appropriate personal protection
equipment (goggles, chemical suit, 
etc.) any time contact with 
chemical might occur.

Warning: Do not turn the stroke 
control knob on the pump unless 
the pump is pumping. Adjustment 
when the pump is off will cause 
damage to the pump.

Warning: Ensure the pump and 
controller are disconnected from 
power when making electrical 
connections and performing 
service.

Installation

Table 1 – Solenoid Pump Capacities

Model Designation

Capacity Per Stroke

SP-15

0.315 ml

SP-30

0.631 ml

SP-45

0.946 ml

Plumbing of the flow meter and tee(s) for the 
injection point fitting(s) should be completed 
before installing the pumper(s). See the 

Installation Guidelines and Operation of 
Ratio:Feeder® Series J Plus Injectors 

for 

installation details.

Installation

Location

Ensure the installation location has all the 
following:

Allow easy access to pump

Allows access to the suction and 
discharge valves for tubing connections

Has access to 120VAC power outlet

Close proximity to other injection 
components

Protected from direct spray

Within 10 feet of chemical stock tank

Plumbing

Chemical Valves

Install the suction valve into the bottom of 
the pump.

Install the discharge valve in the top of the
pump.

Injection Point Fitting (IPF)

Your injection point fitting should be one of the 
types shown in Illustration 1. All serve as an 
injection point check valve, with the first two 
offering additional functions. Refer to the 
instruction sheet specific to your fitting for 
installation and additional information.

H.E. Anderson Co.

2

Solenoid Pump

 10-2017

Priming Vent

Priming Vent 

Knob

Leakage
Drain

Illustration 1: Injection Point Fittings

Содержание SP-15P-VCP

Страница 1: ...o contact us via e mail at info heanderson com Before you call review this manual You may find the answer to your question here But if not reviewing the manual will help us to help you If you need an...

Страница 2: ...the flow meter and tee s for the injection point fitting s should be completed before installing the pumper s See the Installation Guidelines and Operation of Ratio Feeder Series J Plus Injectors for...

Страница 3: ...rp bends that might collapse into a kink Once a proper length piece of tube has been cut place a tube nut onto each end of the tube making sure the threads of the nut face the adapters Press the tube...

Страница 4: ...to the controller and pump before making any electrical connections Solenoid pumps require 120VAC 60hz 0 6 amps 0 066kw Do not remove the grounding terminal on the plug Model P with J Advanced Contro...

Страница 5: ...ould be repeated for each pump if multiple pumps are installed If the pump will not prime properly check all the tubing connections for tight connections and repeat the priming process If prime still...

Страница 6: ...zing temperatures Our warranty does not cover freeze damage Problems With Chemicals Some chemicals may not be compatible with the pumper diaphragm You should check compatibility of a chemical with the...

Страница 7: ...If you have an Anderson injection point fitting Illustration 1 you may service the suction and discharge check valves and Foot Valve Bulkhead Flush Fitting with the system under pressure but you shoul...

Страница 8: ...uctions Other replacement and repair parts 04094 IPF 1 2 Universal Complete 06892 Tubing Bulk 3 8 OD Black for acid 06909 Tubing Bulk 3 8 OD Clear 17087 Suction Pipe 2 piece x 33 H E Anderson Co 8 Sol...

Страница 9: ...Solenoid Pump Instructions Specifications Solenoid Pump 10 2017 9 H E Anderson Co...

Отзывы: