DD & BB Series

Optional Flow Totalizer

The flow totalizer (optional) is a resettable 
counter for accumulating the water flow and is 
equipped with a 10 year battery to retain 
memory. The meter will accumulate flow even if 
injection is turned off.

The  PRIME  ON/OFF Switch

This button (see photo above) allows you to turn
off the injection of chemical, but still record the 
flow if you have the optional counter/totalizer.

To turn the injection OFF

, press 

the button. Injection will stop.

To

 turn the injection ON

, press the 

button. The valve light will flash and the 
injector will make  the first pumping 
stroke.

When priming the injector

, you can 

make repetitive pumping strokes by 
pressing the PRIME ON/OFF switch 
OFF and ON. Be sure to leave the unit 
on after priming.

NOTE: Priming is quicker and easier at a dial 
setting of 10.

You must have at least 30

 

psi of 

back pressure in order for the 
system to operate correctly.

Setting the Pumper

At a dial setting of 10, the feed ratio will be that 
shown on the control panel. (See Photo 1.) That 
is the maximum feed for your unit. If you wish to 
feed less, the feed dial may be set to a lower 
setting.

Example: 

If your injector chemical

:

water feed 

ratio at 10 is 1:200, at a setting of 5 it will feed 
half as much, which corresponds to a 
chemical

:

water feed ratio of 1:400.

Once your injector is set, it is fully operational.

Maintenance & Storage

Servicing the Pumper

Your injector normally requires very little 
maintenance.

For servicing and calibrating your pumper and 
chemical valves, refer to the separate pumper 
and pumper calibration manuals supplied with 
your unit. For pilot valve problems refer to the 
separate pilot valve manual. If you are unable to 
locate them, they are all available on our 
website at 

http://heanderson.com/manuals.php

.

Storage

Warning! Your injector can be 
damaged if allowed to freeze. 
Freeze damage is not covered 
under warranty.

You should take the necessary precautions to 
protect the injector from freezing.

If you remove your injector from the line 

for the winter, you should drain the 
water from it. 

You should also remove the pumper 

from the pilot valve and drain the water 
from it.

DD/DB  04/2015

4

H.E. Anderson Company

Internal 
Switch 
Settings

Feed Ratio 
at 10 on Dial

Model #     Serial # 

 DB/DG Control Panel

Содержание Ratio Feeder DB Series

Страница 1: ...f your control unit Also you should note the number of pumpers of each type and their model numbers found under the adjustment knob stamped into the casting We may not need all this information but having it available at the start can sometimes save a lot of time and trouble for you If you need an additional owners manual for any H E Anderson Company product please visit our website at http heande...

Страница 2: ...DD BB Series DD DB 04 2015 2 H E Anderson Company ...

Страница 3: ... plastic tubing from the chemical tank to the lower hose barb or the lower check valve Connect a short piece of tubing from the discharge valve or upper hose barb to the injection point fitting IPF Connect the 3 4 red hose to the hose barb on the bottom of the pilot valve There will be waste water emitted from this hose during the pumping cycle The volume discharged will be approximately three tim...

Страница 4: ...s the maximum feed for your unit If you wish to feed less the feed dial may be set to a lower setting Example If your injector chemical water feed ratio at 10 is 1 200 at a setting of 5 it will feed half as much which corresponds to a chemical water feed ratio of 1 400 Once your injector is set it is fully operational Maintenance Storage Servicing the Pumper Your injector normally requires very li...

Страница 5: ...DD BB Series DD DB 04 2015 5 H E Anderson Company ...

Страница 6: ...DD BB Series DD DB 04 2015 6 H E Anderson Company ...

Страница 7: ...DD BB Series DD DB 04 2015 7 H E Anderson Company ...

Страница 8: ...DD BB Series DD DB 04 2015 8 H E Anderson Company ...

Страница 9: ...DD BB Series DD DB 04 2015 9 H E Anderson Company 10 1 11 12 2 3 4 3 2 5 6 7 8 9 13 14 15 16 17 ...

Страница 10: ...DD BB Series DD DB 04 2015 10 H E Anderson Company 1 10 4 11 12 2 3 3 2 5 6 7 8 9 13 14 15 16 17 ...

Страница 11: ...l Max Min Pumper Gallons ml strokes min Ratio Ratio Size per Stroke Stroke at max flow DD100 1 100 1 1000 H4 HD 1 06 40 47 3 DD200 1 200 1 2000 H2 HD 1 06 20 47 3 DD400 1 400 1 4000 A10 VCP 1 06 10 47 3 DD1000 1 1000 1 10000 A3 VCP 0 79 3 63 1 DD1200 1 1200 1 12000 P1 BA 3 17 10 15 8 Andy Jr DB models to 20 GPM water flows Model Max Min Pumper Gallons ml strokes min Ratio Ratio Size per Stroke Str...

Страница 12: ...red by H E Anderson Company in the manufacture of our products except to the extent of said component manufacturer s warranty This warranty specifically excludes liability for consequential damages or for charges for labor or expense in making repairs or adjustments or losses of time or inconvenience This warranty gives you specific legal rights and you may also have other legal rights which may v...

Отзывы: