![GYS Powerduction 160L Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/gys/powerduction-160l/powerduction-160l_user-manual_2281206006.webp)
INSTRUCTIONS OF USE
The product is delivered with a three-phase 400V / 50 Hz plug. In order to ensure an optimum use, the product
should be connected to an electrical installation with minimum 25A protection, and protected according to
applicable standards. See the instructions for electrical connections on page 8.
Turn the ON/OFF switch to the ON position. Press the induction heating activation button (4) described on page
5. The light on button 6 blinks indicating that the product is ready to heat. Position the inductor (8) flat on the
part or the area to heat up, placing the open part of the ferrite against the part. Press the trigger (7) on the
handle of the inductor to start heating; if necessary move the inductor in order to heat up a larger surface on
the part. After stopping the heating, decrease the heating power level on the control panel, and secondly only
switch off the product; this way the cooling circuit will reduce the temperature of the inductor before switching
off completely the product.
RESIDUAL RISKS
WARNING!
The machine has been designed to ensure maximum safety. It’s still possible that the operator may get burnt by
touching hot parts.
WARNING!
The machine must not be used near sensitive materials or dangerous explosives, compressed gases, flammable
liquids, electrical equipment.
Metal objects may not be worn close to the inductor, as they will become hot (rings for example).
It is forbidden for people wearing pace-makers or any other biomedical equipment to use this product.
Noise and vibrations
The machine produces a continuous sound level of less than 60dB (A).
The machine does not generate significant vibrations that may cause danger.
Destruction and disposal
Some materials, with which the machine is built, can be recycled; therefore recycling the product should be
performed in accordance with relevant local regulations.
Unpacking and installation
The machine is supplied ready to use. Before operating, you must remove all packaging and place the product in
a suitable place (flat ground, dry and ventilated place).
WARNING!
The installation must enable easy access to all of the machine’s parts. A minimum space around the product
must be respected for good operation and maintenance, without problems and risks for the operator.
Replacing the inductor
WARNING!
The replacement of the inductor should be performed only by authorized staff and only after switching off the
machine.
WARNING!
During maintenance and / or repair, wear protective gloves. Electrically isolate the machine by disconnecting it
from the mains.
WARNING!
It is forbidden to start using the machine if all the metallic side panel have not been screwed back on the
product and if all the safety features are not operational.
053472_01 01 2015_V1
- 6 -
Содержание Powerduction 160L