![GYS GYSPOT 2400 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/gys/gyspot-2400/gyspot-2400_user-manual_2281163003.webp)
III /
DECLARATION OF CONFORMITY
The device described in this manual is conform to the directives EEC 83/336
(Electromagnetic compatibility) and 73/23 (Low Tension) for a professional or advanced use.
This conformity was established in respect to norms EN 50063 of July 1990 (directive Low
Tension) and EN 50199 (directive electromagnetic compatibility).
IV /
CONNECTION OF THE ELECTRIC ALIMENTATION
Single phase alimentation 230V 50Hz protected by a 16A circuit-breaker.
If the device gets the installation protection circuit-breaker to switch on, check that the caliber
of the circuit-breaker is good (16A).
V /
DESCRIPTION OF THE MACHINE
Detection of main
tension indicator
Potentiometer to set
spot duration
Range 2 : levelling
and welding of
undulated wire
Thermal
protection
indicator
Range 1 : welding
of "stars" and
"butterflies".
VI /
USE
Connect the copper earth pad with the terminal of the generator cable.
Firmly fix the earth pad, as close of the working area as possible.
Select the mode to be used thanks to the setting potentiometer :
-
Range 1 (left) : welding of stars or "butterflies" for metal sheet pulling operations,
-
Range 2 (right) : welding of undulated wire or levelling of shocks with the appropriate
copper cap.
Do not set the potentiometer between two setting ranges. In that position, the device does not
make any welding spot.
Place the appropriate tool on the extremity of the gun and firmly tighten the mandrel screw.
Place the electrode on the metal sheet to be repaired. The device will automatically make the
welding spot. To make another point, remove the electrode from the metal sheet during a
short period and place it back.
Thermal protection : in the case of an intensive use, an internal dispositive allows to stop the
device so that it can cool down. A yellow indicator will switch on, on the front panel. The cut
can last several minutes.