GYS GYSPOT 2400 Скачать руководство пользователя страница 3

III /

 

DECLARATION OF CONFORMITY 

The  device  described  in  this  manual  is  conform  to  the  directives  EEC  83/336 
(Electromagnetic compatibility) and 73/23 (Low Tension) for a professional or advanced use. 
This conformity was established in respect to norms EN 50063 of July 1990 (directive Low 
Tension) and EN 50199 (directive electromagnetic compatibility). 

IV /

 

CONNECTION OF THE ELECTRIC ALIMENTATION 

Single phase alimentation 230V 50Hz protected by a 16A circuit-breaker. 
If the device gets the installation protection circuit-breaker to switch on, check that the caliber 
of the circuit-breaker is good (16A). 

V /

 

DESCRIPTION OF THE MACHINE 

Detection of main 
tension indicator 

Potentiometer to set 
spot duration 

Range 2 : levelling 
and welding of 
undulated wire 

Thermal 
protection 
indicator 

 

Range 1 : welding 
of "stars" and 
"butterflies". 

VI /

 

USE 

Connect the copper earth pad with the terminal of the generator cable. 
Firmly fix the earth pad, as close of the working area as possible. 
Select the mode to be used thanks to the setting potentiometer : 

Range 1 (left) : welding of stars or "butterflies" for metal sheet pulling operations, 

Range 2 (right) : welding of undulated wire or levelling of shocks with the appropriate 
copper cap. 

Do not set the potentiometer between two setting ranges. In that position, the device does not 
make any welding spot. 
Place the appropriate tool on the extremity of the gun and firmly tighten the mandrel screw. 
Place the electrode on the metal sheet to be repaired. The device will automatically make the 
welding spot. To make another point, remove the electrode from the metal sheet during a 
short period and place it back. 
Thermal protection : in the case of an intensive use, an internal dispositive allows to stop the 
device so that it can cool down. A yellow indicator will switch on, on the front panel. The cut 
can last several minutes. 