GENEGYS 515 WSF : foreside (higher part) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
GENEGYS 515 WSF : foreside (lower part) 
 

 
Selection indicator 
of value 
(VOLTAGE or 
WIRE SPEED) 

Indicator of 
VOLTAGE or 
WIRE SPEED 
measurment 

Indicator of current 
measurment 

Switch of selection 
for the output 
voltage 

Button of mode 
selection 

Indicators of mode 
selection : 2 times, 4 
times or spot 

 
Control of the 
cooling liquid group

 
Button of WIRE 
quick : it allows for 
new coils to save 
gas 

 
Button of gas drain : 
it allows to avoid 
impurity during 
bottle replacement 
or after a long 
immobilization 

Commutator 
On / Off

 

Yellow indicator of 
thermal switching 

Button of 
spot time 
adjustment 

Operating connector 
for an application 
with a separated 
wire feeder type 
WF. 

Gas adapter of the 
bank 

Filler cap of the cooling 
liquid tank 

Positive terminal for 
the connection to 
contact batch for an 
application with 
separated wire 
feeder type WF 

Negative terminal : 
allows to select an arc 
more or less short.

 see 

page 9

 

 
This terminal depends on 
the welding intensity we 
are connected 

Adapter for cooling 
liquid 

Содержание GENEGYS 510 SF

Страница 1: ...European standards Directive Low Voltage 73 23 CEE of 19th February 1973 decree n 98 1081 of 3rd October 1995 Directive electromagnetic compatibility 89 336 CEE of 3rd May 1989 This conformity is esta...

Страница 2: ...the level of the plug PROTECTION OF EYES AND BODY 1 During the welding process the operator must be protected from the eventual flashes of the electrical arc with protection clothes like leather glove...

Страница 3: ...f VOLTAGE or WIRE SPEED measurement Potentiometer of instructions wire speed except on GENEGYS 510 SF Selection indicator of value wire speed or voltage Selection indicator of value voltage or wire sp...

Страница 4: ...ed wire feeder type WF Commutator on wire feeder choice Position I generator wire feeder origin Position II separated wire feeder WF 212 324 or 344 W in option Terminal application on weak Thickness c...

Страница 5: ...save gas Button of gas drain it allows to avoid impurity during bottle replacement or after a long immobilization Commutator On Off Yellow indicator of thermal switching Button of spot time adjustment...

Страница 6: ...re feeder and screw down bank connection by integrating the pipe in the frontside hole For GENEGYS 510 SF and GENEGYS 515 WSF machine the gas connection of the bank is uniquely made on front side Gas...

Страница 7: ...the coil and put it on the support with taking care to block with base spin then screw down again the swivel For an application with a 5Kg coil or d 200 put the adapter between the support and the co...

Страница 8: ...the cooling circuit must be bleeded from the water To do this operation you have to connect the blue connection of the contact batch 5 or 10 meters on the blue connection of the MIG generator Inject c...

Страница 9: ...1 5 0 8 A3 A4 A5 70 100 2 4 4 6 I I 2 0 8 1 A5 A6 A7 90 130 3 5 6 8 I 3 0 8 1 B1 B2 120 160 4 5 7 11 I 4 5 1 1 2 B3 B4 B5 150 250 4 6 7 12 II 5 7 1 1 2 B6 B7 230 330 4 7 7 15 II 7 9 1 2 1 6 C1 C2 C3 3...

Страница 10: ...EGAZ value This value can be modified by pressing on or If you press again on you will adjust the POSTGAZ time POS on the higher display If you press a third time you will adjust the late time to the...

Страница 11: ...ntrol the earth cable connection and clamp state Control the torch gate The WIRE rubs down after the rollers Covering WIRE guide crushed Locking of the WIRE in the torch No capillary tube WIRE quick t...