CALIBRATION CASE CALIWELD
EN
Fig. 16: Validation page
Before starting the recording, several information must be filled on the validation page in the following sections:
• «Miscellaneous»
19
:
- temperature: the actual temperature is indicated, but can be changed if necessary,
- the date,
• «Recording measurement»: two modes available , manual and automatic (see section «Recording»)
22
,
• «Channels»: indicates the measured values in the selected channels
22
,
• «Points»: indicates the point being mesured (10 points to be measured according to the standard)
23
,
• The «Next point« button: moves to a new point
24
,
• The «Back» button to go back to the «calibration» page
25
.
• The «Start welding» button (n°
21
is a remote control of the load).
RECORDING
Recording the values can be done manually or automatically.
«Manual Recording»
In the «Measurement recording» section, tick the box «Manual». Start the welding (n°
21
fig. 16), and at the chosen time click on the «START» box
The recording of the welding bead starts. The software saves the welding beads measurements and compares them with the target value given when the
list of points is created. The red boxes become green when the given values show a correct gap between the measurement and the target value (see the
section «welding bead values analysis»). Click on the
box to stop recording the welding bead (according to the standard, the recording time must
be at least 10 seconds). Go to the next spot and repeat this operation until the 10 spots are recorded.
Remark : the recording can be repeated as many times as needed by clicking again on the START box and then STOP box.