19
GYSFLASH 30-24 HF
EN
ADVANCED MENU
This menu controls the advanced parameters of the charger.
To move from one parameter to another push the Select key :
SELECT
Activation «Change battery» > Activation «Power Supply» > Activation «Expert Curve» (> Adjusment of the
«Expert Curve» parameters)
• CHANGE BATTERY mode activation:
To activate the CHANGE BATTERY mode, select «ADVANCED MENU |
Change bat: ON». Now this mode will be accessible from the mode list.
• POWER SUPPLY mode activation:
To activate the POWER SUPPLY mode, select «ADVANCED MENU | Power
Supply: ON». Now this mode will be accessible from the mode list.
• «EXPERT» curve activation:
To activate the «RECOV» curve, select «ADVANCED MENU | Expert curve:
ON». Now this curve will be available in the charging curves list from the
CHARGE mode.
• Parameters adjustment of the «Expert» curve:
If the charging curve is activated, the charging curve parameters can be
adjusted (type IU
0
I
0
U):
- Unominal:
Battery nominal voltage (6V, 12V or 24V).
- Ucharge:
Charge voltage adjustable from 6.0 to 30.0V (Step 7).
- Urecovery:
Recovery voltage adjustable up to 30.0V.
If the value «OFF» is selected the recovery function is inactive (Step 2
and 4).
- Ufloating:
Floating voltage adjustment.
If the value «OFF» is selected the floating function is inactive (Step 9).
- Trecovery:
Maximum time for shorted cells recovery, adjustable from
1h to 12h (Step 2).
- Trefresh:
Time for the refreshing phase adjustable from 1h to 12h. If
the value «OFF» is selected, the refresh function is not activated (Step 8).
- T desulfat :
Maximum time of the desulfation phase adjustable from 1h
to 12h (Step 4).
- T ch_max:
Maximum charging time (Step 7 and 6).
- T ch_min:
Minimum charging time (Step 7 and 6).
- Urefresh:
Maximum voltage during refresh (Step 8).
- OCP (Over Charge Protection):
Maximum percentage of the nominal
capacity that can be injected before protection.
a
Warning:
When charging in-situ, a «Urecovery» or «Urefresh» too high
might damage the electronics of the vehicle. We advise NOT to
adjust these settings above 15V.
ADVANCED MENU
ON
OFF
ADVANCED MENU
Power Supply: OFF
EXPERT CURVE
Ufloating:
OFF
EXPERT CURVE
Ucharge:
14.3V
EXPERT CURVE
Urecovery:
OFF
ON
OFF
ON
OFF
ADVANCED MENU
expert curve:
OFF
EXPERT CURVE
T recovery:
5h
1h
2h
...
12h
EXPERT CURVE
T desulfat:
12h
1h
2h
...
12h
EXPERT CURVE
Tch_max:
16h
1h
2h
...
36h
EXPERT CURVE
Tch_min:
0h
0h
1h
...
Tch_max
EXPERT CURVE
T refresh:
5h
OFF
1h
2h
...
12h
EXPERT CURVE
U refresh:
17.0V
Uch
...
30.9V
31.0V
EXPERT CURVE
OCP:
200%
100%
...
245%
250%
ADVANCED MENU
Save?
No
Yes
No
RETURN
ON
OFF
ADVANCED MENU
Change bat.:
OFF
EXPERT CURVE
Unominal:
12V
6V
12V
24V
6.0V
6.1V
...
8.0V
12.0V
12.1V
...
16.0V
24.0V
24.1V
...
30.0V
OFF
Uch
...
29.9V
30.0V
OFF
Uch
...
29.9V
30.0V
OFF
Uch
...
29.9V
30.0V
OFF
6.0V
6.1V
...
Uch
OFF
12.0V
12.1V
...
Uch
OFF
24.0V
24.1V
...
Uch
To save and validate the new settings, select «ADVANCED MENU» | save? Yes»
Push the «MODE» key to exit the «Configuration» menu.