Gymna V-ACTOR II Скачать руководство пользователя страница 11

 

Version 252 of 2018-04-06 

 

4

 

Cleaning 

 
 
 
 
 
 

 
 

 
 
 
 
 
Regular cleaning of the system ensures perfect hygiene and operation of the ShockMaster 
V-ACTOR II handpiece. 
The  handpiece,  in  particular  the  applicator,  must  be  thoroughly  cleaned  and  disinfected 
after each therapy session.  
 

 

 

Remove dust with a dry cloth. 

 

If necessary, remove stains or dirt with a damp cloth. 

 

If required, clean the V-ACTOR with a non-aggressive soap solution or a 70% alcohol 
solution  or  any  other  agent  suitable  for  surface  disinfection  that  does  not  harm  the 
material (lacquered sheet metal). In case of doubt, please consult an accepted list of 
disinfectants (e.g. the VAH list of disinfectants) 

 

Clean  and  disinfect  the  transmitter  after  each  patient  contact.  Screw  off  the 
transmitter screw cap and pull out the transmitter insert if necessary. 

 
 

 

CAUTION 

Flammable  and  volatile  cleansing  and  disinfecting  agents  may 
generate an explosive atmosphere. 

Disconnect the handpiece from the control unit before starting any cleaning and 
overhauling work. 
 

 

ATTENTION 

It is essential to prevent fluid penetrating into the unit or its tubing. 

 

Содержание V-ACTOR II

Страница 1: ...ACCESSORY MANUAL V ACTOR II Handpiece For ShockMaster devices...

Страница 2: ......

Страница 3: ...How to change the transmitters 6 3 Operation 7 3 1 General warnings and safety information 7 3 2 V ACTOR II treatment parameter settings 7 3 3 Functional checks 8 3 4 Standard operation 8 3 5 Treatme...

Страница 4: ...ual contains warnings safety instructions and specific operating instructions in accordance with liability regulations ATTENTION Complete or partial failure to observe the instructions information or...

Страница 5: ...Familiarity with the information and instructions contained in this manual is essential for ensuring efficient and optimal use of the system for avoiding hazards to personnel and equipment and for ob...

Страница 6: ...ptional accessory for the ShockMaster control units which may be used to complement the radial shockwave therapy The V ACTOR II handpiece allows the treatment of soft tissue with high frequency pulses...

Страница 7: ...pment transport 2 2 Scope of the supply V ACTOR II with 2 applicators 25mm and 40mm 2 3 Handpiece connection NOTE Please also refer to the separate operating instructions of your control unit Connect...

Страница 8: ...on is initially released then the plug is pulled out of the handpiece connector 2 2 3 1 Compatibility The V ACTOR II handpiece can be connected to the ShockMaster control units from the manufacturer G...

Страница 9: ...onnect to the ShockMaster control units 3 2 V ACTOR II treatment parameter settings After connecting the V ACTOR II handpiece the control unit automatically recognizes V ACTOR II and operating mode wi...

Страница 10: ...he V ACTOR II handpiece to the control unit Set the pressure to an initial value of 2 0 bar and a frequency of 20Hz Start the V ACTOR II treatment by pushing the trigger button 3 5 Treatment CAUTION A...

Страница 11: ...r any other agent suitable for surface disinfection that does not harm the material lacquered sheet metal In case of doubt please consult an accepted list of disinfectants e g the VAH list of disinfec...

Страница 12: ...eed in accordance with national regulations At the end of its life time the V ACTOR II must be disposed of as electronic waste 4 2 Repair Repair work on defective equipment must only be carried out by...

Страница 13: ...ions No compressed air supply Leaks on handpiece cable or cable not properly connected Check the cable connection and replace them if necessary Check compressor see User Manual control device No pulse...

Страница 14: ...nd spare parts 6 1 V ACTOR II handpiece ShockMaster V ACTOR II BLACK 338 239 ShockMaster V ACTOR 25mm Applic Black 338 668 ShockMaster V ACTOR 40mm Applic Black 338 679 NOTE For information on various...

Страница 15: ...0 0 5 35 Hz Compressed air input ShockMaster 500 1 5 bar ShockMaster 300 1 4 bar Operating conditions Ambient temperature 10 C 35 C Atmospheric pressure 70 106 kPa Relative humidity 30 75 Storage and...

Страница 16: ...ned products shall be borne by the customer Warranty claims will only be accepted if the handpiece is returned in its complete and original state cleaned and in the case without accessories Missing co...

Страница 17: ...Version 252 of 10 04 2018...