Gymna V-ACTOR II Скачать руководство пользователя страница 1

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

ACCESSORY MANUAL 

V-ACTOR II Handpiece 
For ShockMaster devices 
 

Содержание V-ACTOR II

Страница 1: ...ACCESSORY MANUAL V ACTOR II Handpiece For ShockMaster devices...

Страница 2: ......

Страница 3: ...How to change the transmitters 6 3 Operation 7 3 1 General warnings and safety information 7 3 2 V ACTOR II treatment parameter settings 7 3 3 Functional checks 8 3 4 Standard operation 8 3 5 Treatme...

Страница 4: ...ual contains warnings safety instructions and specific operating instructions in accordance with liability regulations ATTENTION Complete or partial failure to observe the instructions information or...

Страница 5: ...Familiarity with the information and instructions contained in this manual is essential for ensuring efficient and optimal use of the system for avoiding hazards to personnel and equipment and for ob...

Страница 6: ...ptional accessory for the ShockMaster control units which may be used to complement the radial shockwave therapy The V ACTOR II handpiece allows the treatment of soft tissue with high frequency pulses...

Страница 7: ...pment transport 2 2 Scope of the supply V ACTOR II with 2 applicators 25mm and 40mm 2 3 Handpiece connection NOTE Please also refer to the separate operating instructions of your control unit Connect...

Страница 8: ...on is initially released then the plug is pulled out of the handpiece connector 2 2 3 1 Compatibility The V ACTOR II handpiece can be connected to the ShockMaster control units from the manufacturer G...

Страница 9: ...onnect to the ShockMaster control units 3 2 V ACTOR II treatment parameter settings After connecting the V ACTOR II handpiece the control unit automatically recognizes V ACTOR II and operating mode wi...

Страница 10: ...he V ACTOR II handpiece to the control unit Set the pressure to an initial value of 2 0 bar and a frequency of 20Hz Start the V ACTOR II treatment by pushing the trigger button 3 5 Treatment CAUTION A...

Страница 11: ...r any other agent suitable for surface disinfection that does not harm the material lacquered sheet metal In case of doubt please consult an accepted list of disinfectants e g the VAH list of disinfec...

Страница 12: ...eed in accordance with national regulations At the end of its life time the V ACTOR II must be disposed of as electronic waste 4 2 Repair Repair work on defective equipment must only be carried out by...

Страница 13: ...ions No compressed air supply Leaks on handpiece cable or cable not properly connected Check the cable connection and replace them if necessary Check compressor see User Manual control device No pulse...

Страница 14: ...nd spare parts 6 1 V ACTOR II handpiece ShockMaster V ACTOR II BLACK 338 239 ShockMaster V ACTOR 25mm Applic Black 338 668 ShockMaster V ACTOR 40mm Applic Black 338 679 NOTE For information on various...

Страница 15: ...0 0 5 35 Hz Compressed air input ShockMaster 500 1 5 bar ShockMaster 300 1 4 bar Operating conditions Ambient temperature 10 C 35 C Atmospheric pressure 70 106 kPa Relative humidity 30 75 Storage and...

Страница 16: ...ned products shall be borne by the customer Warranty claims will only be accepted if the handpiece is returned in its complete and original state cleaned and in the case without accessories Missing co...

Страница 17: ...Version 252 of 10 04 2018...

Отзывы: