For the installer:
Registration with the communications hub
1. Press button A to enter the main menu
2. Navigate to the 01 - Install window
3. Press and hold button B to initiate commissioning
The meter will display the remaining time in minutes and
the commissioning progress bar:
60 minutes are allocated to allow connections to be made and
to fully commission the meter. There are 4 stages to the process,
represented by the four progress symbols after the colon. In the
example the 1st and 2nd stages have been completed.
The first stage is the communications module successfully
paired with hub (8.11), with the three further stages as per
GBCS. Once successfully commissioned the meter will
automatically quit service mode. The process can be
prolonged for an additional 60 minutes by re-selecting the
01 - Install window and then press and hold button B.
The installer can navigate to the 19 - Quit Service Mode window
to exit installation/service mode. The meter will continue the
commissioning process in the background until it is complete,
however this will disable all service accessible windows.
After quitting service mode / successful commissioning,
access to the service menu is unobtainable unless the
security seals and compartment cover are removed.
This gas meter is approved to the Gas Act 1986: Section (17):
Gas Meters and Regulations 1983
It is compliant with the requirements of
• BS EN 1359: 1999/A1 (2006) and BS EN 16314:2013
• MID Directive (2004/22/EC)
• EMC Emissions EN 16314:2013* Section 4.12 &
ETSI EN 301489-17 v3.1.1 (ETSI EN 301 489-1 v2.1.1)
• EMC Immunity EN 16314:2013* Section 4.12 &
ETSI EN 301 489-17 v3.1.1 (ETSI EN 301 489-1 v2.1.1)
• Directive for Potentially Explosive Atmospheres Directive
(ATEX) 2014/34/EU
• Council Recommendation (1999/519/EC) of 12 July 1999
on the limitation of exposure of the general public to
electromagnetic fields (0 Hz to 300 GHz)
Gas meters must be installed by a Gas Safe registered installer in
accordance with BS 6400.
All warning & safety labels must remain attached to the meter
and be adhered to at all times.
The meter secure perimeter must be inspected for any
tamper attempts at the end of the installation and during
any subsequent meter visit.
All enquiries regarding installation, servicing and
maintenance of this gas meter must be directed to
your energy provider.
Declaration of Conformity
Access Levels
The index has 3 access levels which enable different windows
to authorised users (see list of windows in main booklet):
(A) Always - Screen always visible
(U) User - Screen visible after correct PIN entered
(or PIN disabled)
(S) Service - Screen visible in service access mode
Communications Module Triggering
If the communications module needs waking up, navigate to
this window (03) in the main menu and activate it (press and
hold button B). If the ZigBee is already in an awake state the
action will be ignored.