GW Instek Two Line V-Network GLN-5040A Скачать руководство пользователя страница 1

Two Line V-Network 

GLN-5040A 

USER MANUAL 

GW INSTEK PART NO.  

ISO-9001 CERTIFIED MANUFACTURER 

(ES) Equipements Scientifiques SA - Département 

Tests & Mesures 

- 127 rue de Buzenval BP 26 - 92380 Garches

 

Tél. 01 47 95 99 45 - Fax. 01 47 01 16 22 - e-mail: [email protected] - Site Web: www.es-france.com

Содержание Two Line V-Network GLN-5040A

Страница 1: ...AL GW INSTEK PART NO ISO 9001 CERTIFIED MANUFACTURER ES Equipements Scientifiques SA Département Tests Mesures 127 rue de Buzenval BP 26 92380 Garches Tél 01 47 95 99 45 Fax 01 47 01 16 22 e mail tem es france com Site Web www es france com ...

Страница 2: ...was correct at the time of printing However Good Will continues to improve products and reserves the rights to change specification equipment and maintenance procedures at any time without notice Good Will Instrument Co Ltd No 7 1 Jhongsing Rd Tucheng Dist New Taipei City 236 Taiwan ES Equipements Scientifiques SA Département Tests Mesures 127 rue de Buzenval BP 26 92380 Garches Tél 01 47 95 99 45...

Страница 3: ...TIC DIAGRAM 7 TEST EQUIPMENT SET UP 8 Safety Cautions 8 Test Equipment Set up Schematic Diagram 9 Set up 12 APPENDIX 14 GLN 5040A Specifications 14 ES Equipements Scientifiques SA Département Tests Mesures 127 rue de Buzenval BP 26 92380 Garches Tél 01 47 95 99 45 Fax 01 47 01 16 22 e mail tem es france com Site Web www es france com ...

Страница 4: ...ceivers and spectrum analyzers The product is equipped with an artificial hand function that simulates a handheld type measurement a 9kHz and 150kHz high pass filter selection function that allows the product to select the correct filters according to the relevant standard The GLN 5040A is also suitable for signal phase device conduction disturbance voltage measurement Due to design principles the...

Страница 5: ...s BNC connecting wire 1 Pcs Adaptor BNC F to N type M 1 Pcs User instruction manual 1 Book Warranty card 1 Sheet Test report 1 Sheet ES Equipements Scientifiques SA Département Tests Mesures 127 rue de Buzenval BP 26 92380 Garches Tél 01 47 95 99 45 Fax 01 47 01 16 22 e mail tem es france com Site Web www es france com ...

Страница 6: ...dard GB adapter is included in the product accessories 3 Reference Ground Interface 4mm Jack The Reference ground is used to connect to the EUT earth terminal If there is an independent earth terminal for the EUT that needs to be grounded connect it to this terminal ES Equipements Scientifiques SA Département Tests Mesures 127 rue de Buzenval BP 26 92380 Garches Tél 01 47 95 99 45 Fax 01 47 01 16 ...

Страница 7: ... in 10dB attenuator and pulse limiter 7 ARTIFICIAL HAND This function simulates the effect of a human hand touching metal on a handheld device It made up of a 510Ω and 220pF network In practical applications the 4mm jack terminal should be connected to the human touched metal part of the handheld device ES Equipements Scientifiques SA Département Tests Mesures 127 rue de Buzenval BP 26 92380 Garch...

Страница 8: ...r applying ground protection not for applying a ground reference 2 Power input socket It is mainly used to supply power for the DUT Accessories ES Equipements Scientifiques SA Département Tests Mesures 127 rue de Buzenval BP 26 92380 Garches Tél 01 47 95 99 45 Fax 01 47 01 16 22 e mail tem es france com Site Web www es france com ...

Страница 9: ...anual 7 MAIN SCHEMATIC DIAGRAM ES Equipements Scientifiques SA Département Tests Mesures 127 rue de Buzenval BP 26 92380 Garches Tél 01 47 95 99 45 Fax 01 47 01 16 22 e mail tem es france com Site Web www es france com ...

Страница 10: ...N 5040A must be grounded to ensure personal safety especially when there is no isolation transformer connected If the GLN 5040A is not grounded it may lead to serious electrical shock ES Equipements Scientifiques SA Département Tests Mesures 127 rue de Buzenval BP 26 92380 Garches Tél 01 47 95 99 45 Fax 01 47 01 16 22 e mail tem es france com Site Web www es france com ...

Страница 11: ...uipment Under Test 3 Folding method for power supply wire length 1m 4 EUT power supply interface 5 Output shielded wire A Artificial Mains Network B Isolated Transformer C Receiver ES Equipements Scientifiques SA Département Tests Mesures 127 rue de Buzenval BP 26 92380 Garches Tél 01 47 95 99 45 Fax 01 47 01 16 22 e mail tem es france com Site Web www es france com ...

Страница 12: ...connecting wires 5 ETU power supply interface 6 Artificial hand connecting terminals 7 Conducted interference signal output interface 8 Handheld metal parts made up of several sections connected by conducting wires 9 Grounding terminal 10 Artificial mains network power supply interface 11 Input interface 12 BNC Cable ES Equipements Scientifiques SA Département Tests Mesures 127 rue de Buzenval BP ...

Страница 13: ...A Artificial Mains Network B Receiver C Isolated Transformer ES Equipements Scientifiques SA Département Tests Mesures 127 rue de Buzenval BP 26 92380 Garches Tél 01 47 95 99 45 Fax 01 47 01 16 22 e mail tem es france com Site Web www es france com ...

Страница 14: ... grid and power on to test 7 Use the phase line switch on the GLN 5040A to select different phase lines during the test Note When using the equipment don t open the case don t in a humid explosive or inflammable environment Please ensure the equipment surface is dry and clean before use The maximum voltage should be under 50V when using the AC power supply Please read the user manual carefully bef...

Страница 15: ...s if any problems occur In case of an accident do not attempt to open the case for repair ES Equipements Scientifiques SA Département Tests Mesures 127 rue de Buzenval BP 26 92380 Garches Tél 01 47 95 99 45 Fax 01 47 01 16 22 e mail tem es france com Site Web www es france com ...

Страница 16: ...ralia 10A Model 5 For USA 15A High pass filter alternative 150kHz Voltage division factor between EUT and measuring receiver port 10dB Response threshold of built in pulse limiter 130dBuV RF output BNC female 50Ω Artificial hand function Embodied EUT power supply interface German standard power supply socket Working temperature range 5 C 45 C Storage temperature 40 C 70 C Safety standard Confirm t...

Страница 17: ...61000 3 2 2014 EN61000 3 3 2013 Figure 1 Country specific connector models ES Equipements Scientifiques SA Département Tests Mesures 127 rue de Buzenval BP 26 92380 Garches Tél 01 47 95 99 45 Fax 01 47 01 16 22 e mail tem es france com Site Web www es france com ...