OPERATION
33
Tracking series with common terminal
Connection
CH2
CH1
LOAD
COM
Output rating
0~60V/0~3A or 0~30V/0~6A for CH1 ~ COM
0~–60V/0~3A or 0~–30V/0~6A for CH2 ~ COM
Setting step
1.
Select the output range,
60V(120V)/3A or
30V(60V)/6A. Set the
CH1/CH3 meter switch to
the CH1 position.
60V/3A
30V/6A
CH1
CH3
2.
Set the tracking switch
position to Series, + .
TRAC
KING
INDE
P.
SERI
ES
PARA
LLEL
SPD-3606 User Manual
34
3.
Set the OVP if necessary. In
tracking series mode, set the
Channel2 (Slave) OVP setting to
the maximum level, so that the
OVP trips if the Channel1
(Master) setting is violated. For
OVP setup details, see page22.
O.V.P.
SET
TRIP
4.
Connect the load to the front panel terminals,
c & channel2
−
. Use Channel1 (
−
)
terminal as the common line connection.
CH2
CH1
GND
0 60
V , 3A
0 30
V , 6A
0 60
V , 3A
0 30
V , 6A
Common
5.
Set the output Voltage using
the Channel1 (Master)
Voltage knob. Refer to the
Channel1 (Master) meter for
the output setting level.
VOLTAGE
CURRENT
CH1
MASTER
C.V.
C.C.
CH1 / CH3
CH1(+)~COM Voltage = 23.6V in the above case
CH2(–)~COM Voltage = –23.6V in the above case