background image

Artisan Technology Group 

is your source for quality 

new and certified-used/pre-owned equipment

• 

FAST SHIPPING AND 

DELIVERY

• 

TENS OF THOUSANDS OF 

IN-STOCK ITEMS

•  EQUIPMENT DEMOS
• 

HUNDREDS OF 

MANUFACTURERS 

SUPPORTED

•  LEASING/MONTHLY

 

RENTALS

•  ITAR CERTIFIED

           

SECURE ASSET 

SOLUTIONS

SERVICE CENTER REPAIRS

Experienced engineers and technicians on staff 

at our full-service, in-house repair center

WE BUY USED EQUIPMENT

Sell your excess, underutilized, and idle used equipment 

We also offer credit for buy-backs and trade-ins

www.artisantg.com/WeBuyEquipment

                        

REMOTE INSPECTION

Remotely inspect equipment before purchasing with 

our interactive website at

 

www.instraview.com

LOOKING FOR MORE INFORMATION? 

Visit us on the web at

 

www.artisantg.com

    

for more 

information on price quotations, drivers, technical 

specifications, manuals, and documentation

Contact us:

 

 

(888) 88-SOURCE  |  [email protected]  |  www.artisantg.com

SM

View

Instra

Содержание SPD-3606

Страница 1: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Страница 2: ... another language without prior written consent of Good Will company The information in this manual was correct at the time of printing However Good Will continues to improve products and reserves the rights to change specification equipment and maintenance procedures at any time without notice Good Will Instrument Co Ltd No 7 1 Jhongsing Rd Tucheng City Taipei County 236 Taiwan Artisan Technology...

Страница 3: ... CH2 Independent Mode 26 CH3 Independent Mode 28 CH1 CH2 Tracking Series Mode 30 CH1 CH2 Tracking Parallel Mode 36 REMOTE OUTPUT CONTROL 39 PERFORMANCE VERIFICATION 40 Output Voltage Verification 42 Tracking Series Voltage Verification 45 Output Current verification 47 OVP verification 50 Recording Tables 54 SPD 3606 User Manual 4 FAQ 56 APPENDIX 57 Fuse Replacement 57 Volume Guard Optional 58 Spe...

Страница 4: ... fan vent opening Leave a space around SPD 3606 at least 3cm to the left and right Do not perform measurement at circuits directly connected to Mains Note below Do not disassemble SPD 3606 unless you are qualified as service personnel Measurement categories EN 61010 1 2001 specifies the measurement categories and their requirements as follows SPD 3606 falls under category I Measurement category IV...

Страница 5: ...re 10 C to 70 C SPD 3606 User Manual 8 Power cord for the United Kingdom When using SPD 3606 in the United Kingdom make sure the power cord meets the following safety instructions NOTE This lead appliance must only be wired by competent persons WARNING THIS APPLIANCE MUST BE EARTHED IMPORTANT The wires in this lead are coloured in accordance with the following code Green Yellow Earth Blue Neutral ...

Страница 6: ...n 11 Panel overview Front Panel Overview 14 Rear Panel Overview 17 CV CC CV CC Crossover Characteristics 18 SPD 3606 User Manual 10 SPD 3606 Main Features Performance Low noise 50dB Cooling fan controlled by Heatsink temperature High efficiency power conversion minimum 70 with full load Fast Output On Off response 100ms Low temperature coefficient 100ppm C 3mV 150ppm C 3mA Compact size light weigh...

Страница 7: ...e For 115V 15 AC double wave rectification is used for 230V 15 AC full wave rectification An internal selector automatically switches the rectification circuit accordingly The final DC Voltage reaches 240V 370V CH1 2 Power Stage The Power stage for Channel1 and 2 produce the outputs using the combination of Half bridge converter and Linear regulator The Half bridge converter adopts PWM pulse width...

Страница 8: ...cking parallel mode Channel2 output Current is controlled by Channel1 output Current level LED Display The LED display shows the Channel 1 2 3 output Voltage Current level The A D converter changes the analog signal coming from each channel into digital format to be displayed SPD 3606 User Manual 14 Front Panel Overview VOLTAGE VOLTAGE CURRENT CURRENT OVER LOAD CH3 VOLTAGE OUTPUT CH2 CH1 SLAVE MAS...

Страница 9: ...put exceeds the current rating 3A Channel3 switches from Constant Voltage CV mode to Constant Current CC mode Channel1 2 3 output terminal CH3 0 1 5V 3A Accepts the load cables For cable connection details see page24 SPD 3606 User Manual 16 Channel1 CV CC indicator C V C C Turns green when operating in Constant Voltage CV mode red in Constant Current CC mode For CV CC characteristics see page18 Ch...

Страница 10: ...istics Background SPD 3606 automatically switches between constant voltage mode CV and constant current mode CC according to load condition When the current level is smaller than the output setting SPD 3606 operates in Constant Voltage mode The indicator on the front panel turns green C V The Voltage level is kept at the setting and the Current level fluctuates according to the load condition unti...

Страница 11: ...wer Power Up 21 OVP Over Voltage Protection Set 22 Load Wire Load Cable Connection 24 Output Output On Off 25 SPD 3606 User Manual 20 Installation Location Ventillation space Leave at least 3cm around SPD 3606 to the left and right Cooling fan opening The cooling fan is located on the rear panel Allocate extra space on the back of SPD 3606 so that the cooling fan opening would not become blocked C...

Страница 12: ...output voltage limit before operation When the output voltage exceeds this limit the indicator shows the over voltage status and the output is shut off immediately OVP setup 1 Slide the rear panel switch to the O V P SET position CH3 CH2 CH1 O V P SET NORMAL 2 The OVP indicator on the front panel turns green indicating OVP setup O V P SET TRIP 3 The Voltage meters show the OVP setting level instea...

Страница 13: ...24 Load Cable Connection Standard accessory GTL 104 1 Turn the terminal counterclockwise and loose the screw 2 Insert the cable terminal CH2 GND 0 60V 3A 0 30V 6A 2 1 3 Turn the terminal clockwise and tighten the screw CH2 GND 0 60V 3A 0 30V 6A 3 Banana plug Insert the plug into the socket CH2 GND 0 60V 3A 0 30V 6A Wire type When using load cables other than the attached make sure they have enough...

Страница 14: ...SET mode CH3 CH2 CH1 O V P SET NORMAL Remote control When in remote control mode page39 front panel output control is disabled CV CC red without output Red CV CC indicator when output Off indicates internal error Contact the service center C V C C OUTPUT ON OFF SPD 3606 User Manual 26 OPERATION CH1 CH2 Independent Mode Background Connection Channel1 and Channel2 outputs work independent of each ot...

Страница 15: ...the Output key The Output indicator turns green OUTPUT ON OFF OUTPUT ON OFF SPD 3606 User Manual 28 CH3 Independent Mode Background Connection Channel3 rating is 0 1 5V maximum 3A It works independently from Channel1 and 2 regardless of their modes CH3 CH3 LOAD Output rating 0 1 5V 3A maximum No Tracking Series Parallel Channel3 does not have Tracking Series Parallel mode Also Channel3 output is n...

Страница 16: ... OVER LOAD CH3 SPD 3606 User Manual 30 CH1 CH2 Tracking Series Mode Background Tracking series operation doubles the Voltage capacity of SPD 3606 by internally connecting Channel1 Master and Channel2 Slave in serial and combining the output to a single channel Channel1 Master controls the combined Voltage output level The following describes two types of configuration depending on the common groun...

Страница 17: ...um CURRENT CH2 SLAVE 6 Set the output Voltage and Current using the Channel1 Master knob VOLTAGE CURRENT CH1 MASTER C V C C SPD 3606 User Manual 32 7 Refer to the Channel1 Master meter and indicator for the output setting level and CV CC status CH1 CH3 CH1 MASTER C V C C Current level Channel1 meter reading shows the output Current Channel2 Current control must be in the Maximum position Voltage l...

Страница 18: ...2 Slave OVP setting to the maximum level so that the OVP trips if the Channel1 Master setting is violated For OVP setup details see page22 O V P SET TRIP 4 Connect the load to the front panel terminals channel1 channel2 Use Channel1 terminal as the common line connection CH2 CH1 GND 0 60V 3A 0 30V 6A 0 60V 3A 0 30V 6A Common 5 Set the output Voltage using the Channel1 Master Voltage knob Refer to ...

Страница 19: ...R C V C C CH2 SLAVE C V C C PAR SPD 3606 User Manual 36 CH1 CH2 Tracking Parallel Mode Background Connection Tracking parallel operation doubles the Current capacity of SPD 3606 by internally connecting Channel1 Master and Channel2 Slave in parallel and combining the output to a single channel Channel1 Master controls the combined output CH2 CH1 LOAD Output rating 0 30V 0 12A or 0 60V 0 6A Setting...

Страница 20: ...tor C V C C PAR C V C C PAR 6 Set the output Voltage and Current using the Channel1 Master control knobs Channel2 control knobs are disabled VOLTAGE CURRENT CH1 MASTER C V C C SPD 3606 User Manual 38 7 Refer to the Channel1 meter for the output setting level CH1 CH3 Current level Double the reading on the Channel1 meter In the above case the actual output is 1 84 x 2 3 68A Voltage level Channel1 m...

Страница 21: ...e left two terminals are connected the Output is always Off The front panel Output key is disabled Output always On When the right two terminals are connected the Output is always On The front panel Output key is disabled SPD 3606 User Manual 40 PERFORMANCE VERIFICATION Overview Background Performance verification checks SPD functionality before the operation or at the incoming inspection Recordin...

Страница 22: ...um position VOLTAGE Channel1 2 Current knob Minimum position CURRENT SPD 3606 User Manual 42 Output Voltage Verification Check item Minimum output Voltage accuracy Maximum output Voltage accuracy Voltage meter accuracy Output On Voltage meter accuracy Output Off Connection Digital Multimeter SPD 3606 V A Verification step 1 Set the SPD panel according to the Default setting list page41 2 Connect S...

Страница 23: ...ter reading as the Voltage meter accuracy Out On Then turn the output Off and check the SPD reading again Out Off OUTPUT ON OFF OUTPUT ON OFF Here is the acceptance range and example Channel1 2 3 difference 0 5 of reading 2 digits of Multimeter SPD 3606 User Manual 44 Example Multimeter Out On 30 00V Tolerance 0 005 30 0 2 0 4V Accepted SPD reading Out On 29 6V 30 4V Accepted SPD reading Out Off 2...

Страница 24: ...to the maximum CURRENT 6 Turn On the SPD output OUTPUT ON OFF OUTPUT ON OFF 7 Turn up the SPD Channel1 Voltage knob until the Multimeter reading shows 1 000V VOLTAGE 1 000V Minimum tracking series output voltage 8 Connect the Multimeter to SPD Channel2 and record the reading Here is the acceptance range CH2 0 60V 3A 0 30V 6A Channel2 0 985V 1 015V 9 Connect Digital Multimeter back to SPD Channel1 ...

Страница 25: ... Current knob to the maximum Switch the Multimeter Current terminal to high current range CURRENT Maximum output Current 8 Record the Multimeter reading as the Maximum output Current Here is the acceptance range Channel1 2 6 15A 6 25A Channel3 3 05A 3 15A Current meter accuracy 9 Compare and record the difference between the SPD Current meter and the Multimeter reading as the Current meter accurac...

Страница 26: ...nimum OVP setting accuracy Maximum OVP functionality Maximum Connection SPD 3606 No connection Verification step 1 Set the SPD panel according to the Default setting list page41 2 Power up SPD 3 Set the OVP setting switch to the O V P SET position CH3 CH2 CH1 O V P SET NORMAL 4 The O V P indicator on the front panel turns green O V P SET TRIP O V P SET TRIP 5 Turn down the OVP setting terminal to ...

Страница 27: ...ctionality Here is the acceptance range Channel1 2 0 5V 1 5V Channel3 0 00V 1 00V SPD 3606 User Manual 52 12 Turn Off the SPD output OUTPUT ON OFF OUTPUT ON OFF 13 Set the OVP setting switch to the O V P SET position CH3 CH2 CH1 O V P SET NORMAL 14 The O V P indicator on the front panel turns green O V P SET TRIP O V P SET TRIP 15 Turn up the OVP setting terminal to maximum CH1 INCREASE Maximum OV...

Страница 28: ... step 3 to 22 for Channel3 SPD 3606 User Manual 54 Recording Tables Output voltage verification Minimum Maximum Item Channel Min limit Result Max limit CH1 30mV 0mV Minimum Output Voltage CH2 30mV 0mV CH3 0mV 100mV CH1 61 5V 62 5V Maximum Output Voltage CH2 61 5V 62 5V CH3 5 2V 5 3V Output voltage verification Meter accuracy Tolerance 0 5 Multimeter 0 2 V Channel Multimeter Tolerance SPD On SPD Of...

Страница 29: ...ivate remote control For details see page39 The OVP setting switch on the rear panel is on the SET side In this case set the switch to the Normal side The OVP indicator is red In this case change the OVP setting to higher value or remove the over voltage condition Note that in several conditions the Output key automatically turns Off to avoid harmful condition For details see page25 Q2 The CV CC i...

Страница 30: ...which replaces the Channel 1 and 2 output knobs to prevent accidentally changing the output level This feature is useful for automated testing at fixed output level such as assembly line inspection Applicable knobs Channel 1 Voltage and Current knob Channel2 Voltage and Current knob CH2 CH1 Attach volume guard 1 Pull out the original knob Channel2 current knob for example VOLTAGE CURRENT CH2 SLAVE...

Страница 31: ...e Voltage Up 10 90 100ms 95 rating load Voltage Down 90 10 100ms 10 rating load OVP Accuracy 0 5 of reading 0 5V Meter Type 3 digits 0 5 LED display Accuracy 0 5 of reading 2 digits Resolution 100mV 10mA Insulation Chassis and Terminal 100MΩ or above DC 1000V Chassis and AC cord 100MΩ or above DC 1000V Voltage 100ppm C 3mV Temperature Coefficient Current 150ppm C 3mA Remote Control Output On Off F...

Страница 32: ...nsients EN 61000 4 4 2004 Surge Immunity EN 61000 4 5 1995 A1 2001 Conducted Susceptibility EN 61000 4 6 1996 A1 2001 Power Frequency Magnetic Field EN 61000 4 8 1993 A1 2001 Voltage Dip Interruption EN 61000 4 11 2004 Safety Low Voltage Equipment Directive 73 23 EEC amended by 93 68 EEC Safety Requirements IEC EN 61010 1 2001 SPD 3606 User Manual 62 INDEX block diagram system 11 caution symbol 5 ...

Страница 33: ...ly power on off 21 safety instruction 6 socket overview 17 specification 60 switch overview 14 rear panel diagram 17 remote output control disable manual control 25 setup 39 terminal overview 17 service operation about disassembly 6 contact point 56 tracking mode parallel 36 parallel indicator overview 16 series 30 specification 59 tracking series common ground 33 tracking switch automatic output ...

Страница 34: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...