PSU Series Programming Manual
96
parameter
MIN
Minimum current level.
MAX
Maximum current level.
Example
SOUR:CURR:LEV:IMM:AMPL?
38.000
Returns the current level in amps.
[:SOURce]:CURRent[:LEVel]:TRIGgered
[:AMPLitude]
Set
Query
Description
Sets or queries the current level in amps when a
software trigger has been generated.
Syntax
[:SOURce]:CURRent[:LEVel]:TRIGgered[:AMPLitude]
{<NR2> (A)| MINimum|MAXimum}
Query Syntax
[:SOURce]:CURRent[:LEVel]:TRIGgered[:AMPLitude]?
Parameter
<NR2>
0%~105% of the rated current output in
amps.
MIN
Minimum current level.
MAX
Maximum current level.
Return Parameter <NR2>
Returns the current level.
Example
SOUR:CURR:LEV:TRIG:AMPL?
38.000
Returns the maximum possible current level in
amps.
[:SOURce]:CURRent:LIMit:AUTO
Set
Query
Description
Enables or disables the limit on the current
setting.
Syntax
[:SOURce]:CURRent:LIMit:AUTO {<bool>|OFF|ON}
Query Syntax
[:SOURce]:CURRent:LIMit:AUTO?
Parameter
OFF | 0
Disable the setting current limit