REMOTE CONTROL
35
Command Set
L
Query
Description
The L query returns all the status values of the
power supply.
Query Syntax
L<CR>
ASCII
4C 0D
HEX
Return Parameter Vvv.vvAa.aaaWwww.wUuuIi.iiPpppFf
1
f
2
f
3
f
4
f
5
f
6
<CR><LF
>
Character
Description
V
Voltage unit
vv.vv
Voltage value (5 characters, 2 decimal
places)
A
Current Unit
a.aaa
Current value (5 characters, 3 decimal
places)
W
Power unit
www.w
Power value (5 characters, 1 decimal
place)
U
Voltage limit unit
uu
Voltage limit value (2 characters, no
decimal)
I
Current limit unit
i.ii
Current limit value (4 characters, 2
decimal places)
P
Power limit unit
ppp
Power limit value (3 characters, no
decimal)
F
Status Byte character