PSP Series User Manual
42
SV+
Command
Description
The SV+ command increases the voltage output
by 1V (coarse mode) or 1mV(fine mode).
20.00V
21.00V (coarse mode)
20.00V
20.01V (fine mode)
Syntax
SV+<CR>
ASCII
53 56 2B 0D
HEX
Example
SV+<CR>
Increases the voltage output by
one unit.
SV-
Command
Description
The SV- command decreases the voltage output
by 1V (coarse mode) or 1mV(fine mode).
20.00V
19.00V (coarse mode)
20.00V
19.99V (fine mode)
Syntax
SV-<CR>
ASCII
53 56 2D 0D
HEX
Example
SV-<CR>
Decreases the voltage output by
one unit.
SU+
Command
Description
The SU+ command increases the voltage limit by
1V.
Syntax
SU+<CR>
ASCII
53 55 2B 0D
HEX
Example
SU+<CR>
Increases the voltage limit by one
unit.
All manuals and user guides at all-guides.com