OPERATION
67
Hold Measurement
The Hold Measurement function retains the current measurement
data and updates it only when it exceeds the set threshold (as a
percentage of the retained value).
Applicable
measurements
The hold function can be used with the
following basic measurement functions:
ACV, DCV, ACI, DCI, Ω, Hz/P, TEMP
Procedure
1.
Press the HOLD key.
2.
The measurement reading appears on the
primary display and the hold threshold on the
secondary display.
Display
REAR
GPIB
CV
CC
SWEEP
FILT
RCL
STO
COMP
2ND
dBm
EXT
SHIFT
ERR
LIMIT
AUTO
MATH
4W
2W
DC
AC
V
m
m
W
k
M
S
F
C
m
dB
%
A
V
m
m
Hz
W
k
M
W
S
F
C
RMT
MAX
MIN
REL
HOLD
S
M
F
AUTO
4W
2W
DC
AC
n
μF
Measurement
reading
Hold
threshold
Set the Hold
Threshold
Use the Up and Down arrow keys to select a
hold threshold level, as a percentage.
Range
0.01%, 0.1%, 1%, 10%
Deactivate Hold
Measurement
Press the HOLD key for 2 seconds to deactivate
the hold measurement, or simply activate
another measurement function.