8. When the LCD display shows the icon, “   ”, it 

indicates that the battery should be replaced to 

ensure the measurement accuracy. Take out the 

battery from the clamp meter when the meter 

has not been used for a long time.

9. Refrain from altering the internal wiring of the 

clamp meter to prevent damage to the meter or 

harm to the operator.

10.Refrain from storing or using the clamp meter in 

the environments with explosive elements, 

flammables, high temperatures, high humidity or 

strong electromagnetic fields.

11.Clean the clamp meter case with a soft cloth and 

neutral detergents. Do not use abrasive 

materials or solvents to prevent corroding the 

case, damage to the instrument and to prevent 

danger to the operator.       

GCM-407 User Manual

GCM-407 User Manual

IV. Electrical Symbols

   

This symbol signifies the product complies with 

both USA and Canadian requirements

Complies with EU standards

Danger! High voltage!

AC or DC (Alternating current or direct current) 

Diode

Buzzer on-off

DC (Direct current)

AC (Alternating current)

Warning prompt

Ground

Dual insulation

Capacitance

Do not use the clamp meter if the test lead 

insulation is damaged, if the case insulation is 

damaged, if the LCD is not functioning or if the 

clamp meter is not functioning properly.

2. Do not use the clamp meter if the rear cover or 

battery cover is not in place. Failure to do so 

may cause electric shock.

3. Keep fingers behind the finger guard. Do not 

touch any bare wires, conductors, unused input 

terminals, or circuits that are being measured 

when the clamp meter is in operation.

4. Make sure the function switch is in the correct 

position prior to measurement. Do not change 

ranges when using the clamp meter to prevent 

damaging the meter.

5. Refrain from applying more than DC1000V/ 

AC750V to the clamp meter to prevent electric 

shock to the user and damage to the clamp 

meter. 

6. Be careful when measuring RMS voltages 

greater than 30DCV or 30ACV as electric shock 

can occur.

7. Do not measure voltages or current higher than  

the allowable input values. Set the function 

range switch to the highest range possible if the 

magnitude of the measured value is not known. 

Before measuring resistors, diodes or continuity 

in a circuit, the circuit should be powered down 

and all capacitors in the circuit should be 

completely discharged or the measurement 

results could be inaccurate.  

3

4

Содержание GCM-407

Страница 1: ......

Страница 2: ...Restraints 9 3 Electrical Specifications 10 IX Measurement Operating Instructions 13 1 AC Current Measurement 13 2 AC voltage Measurement 15 3 DC voltage Measurement 17 4 Resistance Measurement 18 5 Continuity Test 19 6 Diode Measurement 21 7 Capacitance Measurement 22 8 Non contact AC Voltage Sensing NCV 24 9 Power 25 10 Automatic Shutdown Function 25 X Maintenance and Upkeep 25 1 General Mainten...

Страница 3: ...rrying case If anything is missing or damaged please contact your GW Instek distributor If the instrument is not used in an appropriate manner the safety protec tions could be impaired The unit can be used for MAINS measurements up to CATII 1000V or CATIII 600V according to IEC 61010 031 III Safety Operation Guidelines Please note the warning signs and notes Warnings indicate a condition or action...

Страница 4: ...t use the clamp meter if the test lead insulation is damaged if the case insulation is damaged if the LCD is not functioning or if the clamp meter is not functioning properly 2 Do not use the clamp meter if the rear cover or battery cover is not in place Failure to do so may cause electric shock 3 Keep fingers behind the finger guard Do not touch any bare wires conductors unused input terminals or...

Страница 5: ...ator from touching dangerous areas 3 Trigger Press the trigger to open the clamp head When the trigger is released the clamp head closes 4 Function dial Selects the measurement function or range 5 Function keys HOLD MAX MIN REL 6 LCD display area Displays the measured data and the function icons 7 Input Terminals Input terminals for measure ments other than AC current measurement VI LCD Display Se...

Страница 6: ...Pressing the REL key enters the relative measurement mode In the relative measure ment mode the main display will show the measured value minus the reference value The reference value is obtained from the current measurement when the REL key is pressed This function is only applicable for AC voltage AC current resistance and capacitance measure ment Press the REL key again to exit the relative mea...

Страница 7: ...tery 2 Environment Constraints Working environment Indoor Altitude 2000m Safety codes IEC61010 1 IEC61010 2 032 CAT II 1000V CAT III 600V Pollution grade 2 Operating humidity and temperature 0ºC 30ºC not greater than 80 RH 30ºC 40ºC not greater than 75 RH 40ºC 50ºC not greater than 45 RH Storage humidity and temperature 20ºC 60ºC not greater than 80 RH 3 Electrical Specifications Accuracy of readi...

Страница 8: ...100 Voltage Input impedance 10MΩ Frequency response 40 400Hz 3 DC Voltage Input impedance 10MΩ 4 Resistance Ω 5 Continuity Test GCM 407 User Manual GCM 407 User Manual Open circuit voltage is approx 3 3V measurable PN forward bias 3V Silicon PN typical forward bias is approx 0 5 0 8V 11 12 ...

Страница 9: ...nt conductor should be measured at a time Measuring two or more current conductors may result in erroneous measurement readings 2 Read the AC value directly from the display Note Be sure the conductor to be measured is clamped at the center of the clamp head if not an additional reading error of 1 0 may result GCM 407 User Manual GCM 407 User Manual 3 13 14 The true RMS AC current meaurement accur...

Страница 10: ...fter all measurement operations are completed disconnect the test leads from the EUT When the measured voltage is greater than the safety voltage of 30VAC the LCD will display a high voltage warning prompt When voltages greater than the AC 750V range are input the meter warning prompt will flash and the meter will automatically buzz intermit tently 4 GCM 407 User Manual GCM 407 User Manual 15 16 T...

Страница 11: ...ng prompt will flash and the meter will automatically buzz intermittently 4 Resistance Measurement See Figure 6 1 Insert the red test lead into the Ω input jack and the black test lead into the COM jack 2 Rotate the function dial to the Ω measurement mode Press the SELECT key to select resistance measurement Ω and connect the test leads in parallel to the resistance to be measured 3 Directly read ...

Страница 12: ...rcuit Before measuring in circuit resistors turn off the power from the circuit and discharge any capacitors for best measurement results 5 Continuity Test see Figure 7 1 Insert the red test lead into the Ω input jack and the black test lead in the COM input jack 2 Rotate the function selection switch to the measurement mode Press the SELECT key to select continuity measurement Connect the test le...

Страница 13: ...citors should be discharged to ensure measurement accuracy The open circuit test voltage for the diode measurement is approximately 3 5V Do not input voltages higher than 30VDC or 30VAC or personal injury may result After completing all measurement operations disconnect the test leads from the measured circuit 7 Capacitance Measurement See Figure 9 1 Insert the red test lead into the input jack an...

Страница 14: ...ages to prevent damage to the meter or to prevent personal injury After completing measurement operations disconnect the test leads from the EUT 9 10 23 24 GCM 407 User Manual GCM 407 User Manual 8 Non contact AC Voltage Sensing NCV See Figure 10 In order to sense whether there is AC voltage or an electromagnetic field present place the front end of the clamp meter near the conductor to be tested ...

Страница 15: ...on dial is not turned or a key is not pressed on the clamp within a 15 minute window the display will turn off and the clamp will enter a low power state To wake the meter up press any key Press the SELECT key to turn on the unit with the automatic shutdown disabled X Maintenance and Upkeep See Figure 11 Warning To prevent electric shock keep the protective caps on the test leads when not in use 1...

Отзывы: