Page 13
Lift Electrical Schematic
M
BATTERY
CHASSIS GROUND
CIRCUIT BREAKER
CONNECTORS
MOTOR
MICROSWITCH
DIODE
SWITCH
SOLENOID
SYMBOL
DESCRIPTION
SOLENOID
NC
NO
C
FS8
FS7
FS4
FS12
FS3
RL1
RL2
RL3
RL5
FS6
FS5
RL6
FS2
FS1
MS8
RD(6)
RD(6)
RD(10)
CIRCUIT
SENTRY
POWER
FEED
STUD
BATTERY
OR(12)
BK(10)
BU(12)
OR
OR
UP/FOLD
SOLENOID
DOWN
SOLENOID
FOLD
SOLENOID
PUMP
RD(10)
CIRCUIT
BREAKER
HYDRAULIC
(UP)
M
GROUND
GROUND
BAT.
AUX.
OFF
ON
BAT.
AUX.
J1
1
3
P1
6
5
4
2
1
3
6
5
4
2
DK BU
DK BU
BN
BN
PK
DK GN
DK GN
DK GN
DK GN
OR
YL
BK/GY
WH
DK BU
BN
PK
PK
DK BU
WH
YL
MICROSWITCH
STATION
UP / FOLD
MICROSWITCH
PARTIAL FOLD
MICROSWITCH
NC
NO
C
1
2
3
BK/GY
BN
BN
BN
OR
BN
OR
UNFOLD / DOWN
MICROSWITCH
NC
NO
C
NC
NO
C
YL(16)
YL(16)
YL(16)
BK(16)
BK(16)
BK/GY
BK(16)
WH(16)
WH(16)
WH
YL
OR
BN
BN(16)
WH(16)
BN(16)
RD(16)
UNFOLD
FOLD
UP
DN
SWITCH BOX
BN(16)
RD(16)
RD(16)
LIFT
LIFT
POWER
SWITCH
FS10
MS10
FS9
MS9
FS11
MS11
Notes:
1. Shown with lift in stowed position.
2. All wires 20 gauge unless otherwise noted.