background image

Precautions 

 

Read all of these instructions and save them for later use. 

 

Follow all warnings and instructions on the product. 

 

Product 

Do not cover or block the vent holes in the case. 

Do not insert sharp objects or spill liquid into the LCD monitor through cabinet slots. 
They may cause accident fire, electric shock or failure. 

Disconnect the power plug from the AC outlet if you will not use it for an indefinite period 
of time. 

Do not attempt to service this product yourself, as opening or removing covers may 
expose you to dangerous voltage points or other risks. 

Do not touch the screen directly with your fingers. You may damage the screen, and oil 
from your skin is difficult to move. 

Do not apply pressure to the screen. The LCD is very delicate.  

 

Power 

Use the type of power indicated on the marking label. 

 

Plugs 

Do not remove any of the prongs of the monitor's three-pronged power plug.   

Disconnect the power plug from the AC outlet under following conditions: 

 

If you will not use it for an indefinite period time. 

 

When the power cord or plug is damaged or frayed. 

 

If the product does not operate normally when the operating instructions are 
followed. Adjust only those controls that are covered by the operating 
instructions. Improper adjustment of other controls may result in damage and 
will often require extensive work by a qualified technician to restore the product 
to normal operation. 

 

If the product has been dropped or the cabinet has been damaged. 

 

If the product exhibits a distinct change in performance, indicating a need for 
service. 

 

Power and extension cords 

Do not allow anything to rest on the power cord. 

Do not locate this product where persons will walk on the cord. 

Use the proper power cord with correct attachment plug type. If the power source is 120 V 
AC, use a power cord that has UL and C-UL approvals. If the power source is a 240 V AC 
supply, use the tandem (T blade) type attachment plug with ground conductor power cord 
that meets the respective European country's safety regulations, such as VDE for 
Germany.  

Do not overload wall outlets or power cords. Ensure that the total of all units plugged into 
the wall outlet does not exceed 10 amperes.  

Ensure that the total ampere ratings on all units plugged into the extension cord is not 
above the cord's rating. 

Содержание P15PX-L

Страница 1: ...g is damaged or frayed If the product does not operate normally when the operating instructions are followed Adjust only those controls that are covered by the operating instructions Improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the product to normal operation If the product has been dropped or the cabinet has ...

Страница 2: ...es and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on th...

Страница 3: ...nterference caused by unauthorized modification of this equipment It is the responsibility of the user to correct such interference Caution To meet FCC limits for a Class B computing device a shielded signal cable should be used Canadian Department Of Communications Compliance Statement This equipment does not exceed Class B limits per radio noise emissions for a digital apparatus set out in the R...

Страница 4: ...creen Display controls Package Contents Included with your LCD monitor are following items 15 TFT liquid crystal monitor D sub 15 pin signal cable AC power cable User s manual Audio cable optional RS232 cable for touch screen function optional Product Features High contrast color TFT LCD display support resolution up to XGA 1024x768 Compatible with IBM VGA VESA and Macintosh standards Power manage...

Страница 5: ...e OSD control options on the screen 4 Menu Select Pressing this button pops up the OSD menus on the screen and used to select Down direction the OSD control options on the screen 5 This button is used to adjust the increasing value of the selected OSD control option 6 This button is used to adjust the decreasing value of the selected OSD control option Rear View 1 2 3 4 1 Power Connector This is f...

Страница 6: ...ting with the OSD Control To Display and Select the OSD Functions Pressing or once pops up the OSD function main menu Pressing or a second time to select the different OSD control option To Adjust the Value of the Control Option Pressing button changes the value of the selected OSD control option After adjusting values the monitor will automatically save the changes NOTE The OSD screen will disapp...

Страница 7: ...sed to decrease the vertical interference 1 Select one display pattern from your computer 2 Use and buttons on the LCD monitor to decrease the vertical interference to get the optimal display PHASE This item is used to decrease the horizontal interference 1 Select one display pattern from your computer 2 Use and buttons on the LCD monitor to decrease the horizontal interference to get the optimal ...

Страница 8: ...en Within On Green 36W 3S Off Orange 5W 3S We recommend to switch off the monitor when it is not use for quite a long time Troubleshooting The monitor does not respond after you turn on the system Check if the Power Switch of monitor is turned on Turn off the power and check the monitor s power cord and signal cable for proper connection The characters on the screen are dim Refer to the Controls a...

Страница 9: ...9 59 940 25 175 4 640X480 VESA72 37 861 72 809 31 500 5 640X480 VESA75 37 500 75 000 31 500 6 800X600 SVGA 35 156 56 250 36 000 7 800X600 SVGA 37 879 60 317 40 000 8 800X600 VESA72 48 077 72 188 50 000 9 800X600 VESA75 46 875 75 000 49 500 10 1024X768 VESA60 48 363 60 004 65 000 11 1024X768 VESA70 56 476 70 069 75 000 12 1024X768 VESA75 60 023 75 029 78 750 9 ...

Страница 10: ...25 ms typical Display Color 16M Viewing Angle 120o H x 100o V Input Signal Video R G B Analog 0 7V peak peak Sync TTL Positive or Negative Signal Connector 15 Pin D Sub Front Control Power Switch Menu Select up down Adjust Plug Play DDC1 2B Audio System optional 1W Per Channel Touch Panel optional Resistive Capacitive Type with RS232 connector Power Imbedded AC Input Universal 100 240 V Operating ...

Страница 11: ...Condensation Dimensions HxWxD 408 5 x 390 x 195 mm Weight Net 5 3 Kg Certifications C UL FCC CE Specifications are subject to change without notice WARNING Do not disassemble the monitor Contact your dealer if needed 11 ...

Отзывы: