Dip Switch setting 

 

 

 
 
 
 
 
 
 
 
 
 

1.  Day & Night Time Delay: 2sec. / 4sec.(Default 2sec.) 

- The setting of the delay time from Day(Color) Mode to Night(B/W) Mode or 
from Night Mode to Day Mode. 
 

2.  Flickerless Mode: ON / OFF(Default OFF) 

-  If  the  NTSC  system  camera  is  used  with  50Hz  fluorescent  lighting,  the 
screen will flicker. In this case, set the flickering switch to “ON”. 

 
3.  BLC(Back Light Compensation): ON / OFF(Default ON) 

-  When  the  lighting  source  is  behind  of  an  object,  the  object  may  appear 
dark. Set the BLC switch to “ON”, the object will become brighter.   

 
4.  AWB(Auto White Balance): ATW / AWC(default AWC) 

-  ATW(Auto  Tracking  White  Balance):  It  controls  the  screen  color 
automatically  in  the  limited  changing  range  of  the  external  light.  (Color 
Temp. 2,500 ~ 9,500K˚) 
-  AWC(Auto  White  Balance  Control):  It  controls  the  screen  color 
automatically in a wide changing range of the external lighting source. But 
in some environment (Mono-colored or non-whitened) the color control may 
not be available. (Color Temp. 2,000 ~ 18,000 K˚) 

Dip Witch Setting 

NO. 

Function 

ON 

OFF 

Time Delay 

2~3 sec. 

4~5 sec. 

Flickerless 

OFF 

ON 

BLC 

ON 

OFF 

ATW/AWC 

ATW 

AWC 

1

2

3

4

ON

SERVICE  PORT

DIP SWITCH

DC LEVEL VOLUME

10 

  Troubleshooting 

 

If  you  have  trouble  operating  the  camera,  check  the  following  guides  for 
the possible cause of the problem. 

 

• Nothing appears on the screen. 

-> Check the power and video signal line connection. 
-> Check the brightness level of DC Auto Iris Lens. 

 

• The video image is not clear. 

-> Check if the dome cover has lots of dust on the surface.   

Clean the cover with a clean cloth or brush. 

-> Make sure that the screen is not exposed directly to a bright light. 

Adjust the position of the camera if necessary. 

 

• The screen is dark. 

-> Adjust the contrast feature of the monitor. 
-> Check the brightness level of DC Auto Iris Lens. 

 

• The screen does not properly display when IR LEDs Work. 

    -> Check if an object is located within 50cm from the Camera. 
        Move the object away from the camera 50cm + 
    -> Check if the dome cover has dust. 
        Clean the cover with a clean cloth or brush. 

 

 

If you can’t solve the problems with the above guidelines, please contact an 

authorized technician.

Содержание GV-VD550IR

Страница 1: ...ital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interfer...

Страница 2: ...mera at bright objects Never face it with direct sunlight or other extremely bright objects Otherwise blooming or smear may be caused Do not use strong solvents or detergents Wipe the camera with a dry cloth if dirty If it is hard to remove the dirt on the camera use a mild detergent and wipe it gently Before operating please check proper temperature humidity and power source ratings Use the camer...

Страница 3: ...holes on the left and bottom Service Monitor Cable Cable used to monitoring the display screen through portable monitor to adjust the camera view Screws Big screws are used to firmly attach the bracket to the wall or ceiling and small screw is used to connect the bubble and surface by safety cable Rubber Bottom Located at the base housing for weatherproof purpose L Wrench Unscrew and tighten screw...

Страница 4: ...se undesired effects on the product Camera Installation After choosing the dipswitch setup appropriate for your specific application follow the next guidelines 1 Remove the protective sheet from the rubber bottom and attach it on the base housing 2 Fix the base housing on the wall or ceiling with the supplied screws 3 Unscrew the bracket screws and adjust the camera direction by turning the pan br...

Страница 5: ...ble Color Temp 2 000 18 000 K Dip Witch Setting NO Function ON OFF 1 Time Delay 2 3 sec 4 5 sec 2 Flickerless OFF ON 3 BLC ON OFF 4 ATW AWC ATW AWC 1 2 3 4 ON SERVICE PORT DIP SWITCH DC LEVEL VOLUME 10 Troubleshooting If you have trouble operating the camera check the following guides for the possible cause of the problem Nothing appears on the screen Check the power and video signal line connecti...

Страница 6: ...on 0 Lux IR LED ON 0 5Lux IR LED OFF White Balance ATW AWC selectable LED Wavelength 850nm Visible Video Output VBS 1 0 Vp p 75 Ω load Lens 3 8 9 5mm Vari focal DC Auto Iris F1 2 Day Night Lens Power Supply AC24V 10 DC12V 10 Normal 2 5VA Max 4 0VA AC24V IR LED ON Power Consumption Normal 250mA Max 500mA DC12V IR LED ON Operating Temp 14 F 122 F 10 C 50 C Operational Humidity 90 RH max Dimension 14...

Страница 7: ...al Information Surface ZNDC Zinc Die Casting Bubble PC Poly Carbonate Glass Thickness 2 mm 14 GVI Security Inc 2801 Trade Center Dr Suite 120 Carrolton TX 75007 Toll Free 888 595 2288 Fax 972 245 7333 www gviss com MADE IN KOREA ...

Отзывы: