12
Self Diagnosis Functions
Our company provides the thoughtful services for customer.air conditioners had been installed self
diagnosis system to display the information for the units.
Self-check information
Self-check code of luminotron/
(Self-check code of running
lamp)
Digital self-check code/
(Polychrome screen self-check
code
Defrost indication
Flicker 1 time/1s
Indicates “dF”or Heating icon
flash
Anti cold wind
Flicker 1 time/1s
Fan motor picture not running
Room temperature sensor fault
Flicker 1 times/8s
E2
Coil temperature sensor
Flicker 2 times/8s
E3
External feedback fault
Flicker 7 times/8s
E7
Outdoor tube temperature
sensor faults
Flicker 4 times/8s
E1
(EEPROM)communication
failures
Flicker 6 times/8s
E6
North American
Environment outside
temperature erceeds the scope
Flicker 1 times/1s
FF
Note:Above self check information is commonly applicable in our most air conditioners, but some
are special, you can refer to the User‘s Manual for information or contact the dealer or authorized
maintenance people for help.