Gutermann Aquascope 2 Скачать руководство пользователя страница 9

AQUASCOPE 2

Version 1.2

8/7

7. Wearing the Control Unit

Fig.7 Waist Mounted Control Unit

Attach  the  AQUASCOPE  2 control  unit around  the  waist using the
webbing strap and quick release clips provided. The waist band can be
adjusted  to  suit.  An  alternative  method  of  holding  the  control  unit  is
around the neck using the waist band.

8. Battery replacement

At the back of the amplifier is the battery compartment. Please lift the

battery  compartment  cover.  There  are  4  LR6  (AA)  size alkaline
batteries.  When  the  battery  charge  indicator  on  the  display  suggests
replacing  the  batteries,  please  make  sure  that  all  4 batteries  are
replaced at the same time. When inserting the batteries please observe
the correct direction (+ and – according to the indicated position).

9. Technical Specifications

1.

The  control  unit  should  be  manufactured  from  a  high  strength
PVC  material  that  is  resistant  to  exposure  from  high  levels  of
UV exposure.

2.

Power supply with 4 LR6 or “AA” Alkaline batteries.

3.

The System has a Frequency range of 40 – 5000Hz

4.

The control unit has amplification of 60DB or more.

5.

The Sensitivity in the hand probe is 15v/g or more.

Содержание Aquascope 2

Страница 1: ...Operating Manual V1 2 Date 24 11 2016 ...

Страница 2: ...ing the Headphones 4 6 The Hand probe Microphone 5 6 1 Techniques using the hand probe Microphone with Rods 5 6 2 How to find leaks with the AQUASCOPE 2 listening stick 6 6 3 Techniques using the hand probe Microphone with Tripod 7 6 4 How to find Leaks with the AQUASCOPE 2 Tripod foot 7 7 Wearing the Control Unit 8 8 Battery replacement 8 9 Technical Specifications 8 10 Disposal 9 11 Trouble Shoo...

Страница 3: ...ons in a safe place 1 1 Symbols Warning of dangerous situations that can cause injury and damage to the devices Warning The Aquascope kit contains a very powerful magnet The operation of cardiac pacemakers and implanted defibrillators can be influenced People with cardiac pacemakers and implanted defibrillators are not permitted anywhere near this product Important notes and tips are a sign Info p...

Страница 4: ...manual or contact your Gutermann distributor When using the software or the equipment make sure you adhere to any applicable regulations in particular traffic regulations 1 3 Warning The Aquascope 2 kit contains a very powerful magnet The operation of cardiac pacemakers and implanted defibrillators can be influenced People with cardiac pacemakers and implanted defibrillators are not permitted anyw...

Страница 5: ... configuration All Configuration Types include Amplifier control unit with waist belt Stereo Headphones Connection Cable Hand probe microphone 2 x Probe rods including 1 with a tip 4 How to Switch on the Amplifier Turn the volume control knob clockwise to turn the amplifier on When the headphones and microphone are connected a comfortable volume level can be set Note In order to save battery consu...

Страница 6: ... on pipes and fittings 6 1 Techniques using the hand probe Microphone with Rods The following photos show example methods of using the AQUASCOPE 2 hand probe Caution when probing through the soil it s highly recommended that a certified insulated probe such as a punch bar is used This helps prevent the possibility of electrical shock or damaging the aluminium rods while probing through the ground ...

Страница 7: ...h other underground services Check with your company Health and Safety Officer before proceeding with this method 1 Listen on all fittings in an area making note of the noise frequency and characteristics It is usual to listen at each location for a period of 10 seconds waiting for background noise to stop If there is noise generated from consumption pumps road works or heavy traffic you will need...

Страница 8: ...ed or held in a still position during operation 1 Localise the leak position with noise loggers or an electronic listening stick If a Correlator is available this can be used to narrow down the location to a much smaller area 2 It is best practice to locate the pipe position with a pipe locator 3 Follow the path of the pipe listening for the leak at 1 meter intervals 4 When the location with the h...

Страница 9: ...4 LR6 AA size alkaline batteries When the battery charge indicator on the display suggests replacing the batteries please make sure that all 4 batteries are replaced at the same time When inserting the batteries please observe the correct direction and according to the indicated position 9 Technical Specifications 1 The control unit should be manufactured from a high strength PVC material that is ...

Страница 10: ...egulations If an orderly disposal of our products is not possible send the unit to us We dispose our products environmentally friendly Address see imprint 11 Trouble Shooting Fault Possible cause Solution No Sound A Damaged cable or Headphones Headphone Volume control is too low Replace connection cable or headphones Increase headphone volume control Sound in 1 earpiece Headphone Replace Headphone...

Отзывы: