background image

GENERAL INSTALLATION DATA

This equipment is designed and sold for commercial use only by personnel trained and 

experienced in its operation and is not sold for consumer use in and around the home nor for use 

directly by the general public in food service locations. For equipment to be used by the general 

public, please contact the factory.
This gas appliance  is equipped for the types of gas indicated on the nameplate mounted on the  

front panel. It is shipped adjusted for use on natural gas.

The installation of the Appliance should conform to the NATIONAL FUEL GAS 

CODE "ANSI Z223.1 - LATEST EDITION" AND ALL LOCAL GAS COMPANY 

RULES AND REGULATIONS.

IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE CURRENT 

CAN/CGA-B149.1 NATURAL GAS INSTALLATION CODE OR CAN/CGA-B149.2 

PROPANE INSTALLATION CODE AND LOCAL CODES WHERE APPLICABLE.

WARNING: Improper installation, adjustment, alteration, service or maintenance 

can cause property damage, injury or death. Read the installation, operating and 

maintenance instructions thoroughly before installing or servicing the equipment.

FOR YOUR SAFETY 

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS 

IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. KEEP THE APPLIANCE AREA 

CLEAR AND FREE FROM COMBUSTIBLES.

This appliance, its pressure regulator and its individual shutoff valve must be disconnected from 

the gas supply piping system during any pressure testing of that system at test pressures in excess 

of 1/2 PSIG. This appliance and its pressure regulator must be isolated from the gas supply piping 

system by closing its individual manual shutoff valve during any pressure testing of the gas supply 

piping system at test pressures equal to or less than 1/2 PSIG. For your protection, we recommend 

a qualified installing agency install this appliance. They should be familiar with gas installations and 

your local gas requirements. In any case, your gas company should be called to approve the final 

installation. In addition, there should be posted, in a prominent location, detailed instructions to be 

followed in the event the operator smells gas. Obtain the instructions from the local gas supplier.

LEVELING UNIT

Units are shipped with feet detached.  To attach feet, remove the grates, lay unit on it's side and 

screw feet into sockets on bottom.  Level unit by adjusting the (4) feet which have an adjustment of 

1-3/4" for accurate and perfect line-up with other Star-Max series units. 

DO NOT REMOVE FEET.

GAS PIPING

Gas piping shall be new, clean and of such size and so installed as to provide a supply of gas 

sufficient to meet the full gas input of the appliance. If the appliance is to be connected to existing 

piping, it shall be checked to determine if it has adequate capacity. Joint compound (pipe dope) 

shall be used sparingly and only on the male threads of the pipe joints. Such compounds shall be 

resistant to the action of L.P. gases. 

WARNING:

 Any loose dirt or metal particles which are allowed to enter the gas lines on the 

appliance will damage the automatic valve and affect its operation. When installing this appliance, 

all pipe and fittings must be free from all internal loose dirt.

CAUTION

CAUTION

Содержание AMHP2

Страница 1: ...1 GAS HOT PLATE MODEL AMHP2 AMHP4 AMHP6 Installation Operation Parts Manual 2M Z15770 Rev 4 12 12 IL2424 ...

Страница 2: ...re not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifications By using the information provided the user assumes all risks in connection with such use MAINTENANCE AND REPAIRS Contact your local authorized service agent for service or required maintenance Please record the model number serial number voltage and purchase date in the...

Страница 3: ...s Sizes available in 12 24 or 36 widths to fit almost anywhere and suitable for a variety of pots and pans High performance 22 000 BTU cast iron burners provide maximum heat distribution and control Heavy duty cast iron grates stand up to constant use Standing pilot for each burner for easy ignition Manual on off control valve has 1 4 turn for easy temperature control Cool to the touch stainless s...

Страница 4: ...liance and its pressure regulator must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 PSIG For your protection we recommend a qualified installing agency install this appliance They should be familiar with gas installations and your local gas require...

Страница 5: ...ent entry of dirt Do not remove this seal until the actual connection is made to the gas supply line CHECKING FOR GAS LEAKS Soap and water solution or other material acceptable for the purpose shall be used in locating gas leakage Matches candle flame or other sources of ignition shall not be used for this purpose AIR SUPPLY Provisions for adequate air supply must be furnished AIR INTAKES IN BOTTO...

Страница 6: ...converting the regulator to natural gas 1 Set regulator outlet pressure to 10 water column A 1 8 pipe plug on the manifold can be removed for attaching a pressure gauge Remove the slotted cover from the pressure regulator and invert the plug Replace the cover on the regulator and plug on the manifold Regulator is now set at 10 W C 2 Remove natural gas orifices 46 for all models and install propane...

Страница 7: ...7 ...

Страница 8: ...Model AMHP Gas Hotplate SK2573 Rev 3 13 12 1 2 3 4 5 6 8 9 10 13 14 15 22 16 17 18 19 20 21 11 12 7 ...

Страница 9: ... 4 1 2 13 AMHP2 11 I4 Z6024 1 PAN 12 AMHP2 I4 Z6025 PAN 24 AMHP4 I4 Z6026 PAN 36 AMHP6 12 2C 8833 AR SCREW 8 18X1 2 HEX STL NP AMHP2 13 2R W498 2 KNOB RED AMHP2 4 AMHP4 6 AMHP6 14 2M Z15723 1 FRONT GRAPHIC AMHP2 2M Z15724 AMHP4 2M Z15725 AMHP6 15 I4 Z15873 1 FRONT PANEL 12 AMHP2 I4 Z15874 FRONT PANEL 24 AMHP4 I4 Z15875 FRONT PANEL 36 AMHP6 16 2V Y8832 2 VALVE MANUAL GAS AMHP2 4 AMHP4 6 AMHP6 17 2A...