User Manual

Wrist Blood Pressure Monitor

AP-WBPM810

To use the monitor correctly and safely, please read the manual 

thoroughly.

Thank you very much for selecting AccuraPulse Wrist Blood Pressure 

Monitor AP-WBPM810.

Please keep this manual well in order to reference in future.

Questions/Warranty: [email protected]

Wrist Type

Version:1.0

Distributed By: Gurin Products LLC

2522 Chambers Road, Suite 100 Tustin, CA-92780 USA

Questions/Warranty: [email protected]

2018-05-10

技术要求:
1、黏合不可露胶
2、保持印刷面板上的清洁
3、注意套印的准确性
4、表面处理不可爆开

5、结构工艺以结构受控图为准
6、颜色参考:

产品型号

材质

尺寸

70g 书写纸

70*95 mm

单黑

产品名称

血压计

-

TMB-1580-006

李秋燕    2018-05-10

罗佳钰    2018-05-10

谭文昊    2018-05-10

TMB-1580-006-GB-08

PO#2F3133-TMB-1580-006-GB-08-说明书-A2

共   16   张

第   1   张

A/2

对应结构图纸

印色

1:1

-

表面处理

Содержание Accura Pulse AP-WBPM810

Страница 1: ...M810 Please keep this manual well in order to reference in future Questions Warranty Support gurinproducts com Wrist Type Version 1 0 Distributed By Gurin Products LLC 2522 Chambers Road Suite 100 Tus...

Страница 2: ...OOD PRESSURE 20 What are systolic pressure and diastolic pressure What is the standard blood pressure classification Why does my blood pressure fluctuate throughout the day Why do I get a different bl...

Страница 3: ...starts inflating the cuff Meanwhile the unit detects pressure oscillation generated by beat to beat pulsatile which is used to determine the systolic pressure and diastolic pressure as well as pulse r...

Страница 4: ...d impairment of patient blood circulation CAUTION When measurement please avoid compression or restriction of the connection tubing The device cannot be used with HF surgical equipment at the same tim...

Страница 5: ...re between uses until it is ready for intended use At least 30 min required for ME equipment to cool from the maximum storage temperature between uses until it is ready for intended use This equipment...

Страница 6: ...ow happen shows Display is dim Display does not light up CUFF Type BF applied part BATTERY COMPARTMENT CAUTION Do not use new and used batteries together Do not use different types of batteries togeth...

Страница 7: ...using your blood pressure monitor so that a time stamp can be assigned to each record that is stored in the memory year 2014 2054 time format 24 H 12 H 1 2 Press the button to change the TIME FORMAT b...

Страница 8: ...loose the measurement will not be accurate Sit comfortably with your tested wrist resting on a flat surface Place your elbow on a table so that the cuff is at the same level as your heart Turn your pa...

Страница 9: ...1 2 The date and time will display alternately The corresponding time is 9 10 The corresponding date is May 11 When the monitor is off press button to show the average value of the latest three measu...

Страница 10: ...signed to the first 1 record All other records are pushed back one digit e g 2 becomes 3 and so on and the last record 60 is dropped from the list CAUTION 3 If you want to check the other user s measu...

Страница 11: ...oblems with this device such as setting up maintaining or using please contact the SERVICE PERSONNEL of AccuraPulse Don t open or repair the device by yourself Please report to AccuraPulse if any unex...

Страница 12: ...asurement position so please take the measurement under the same conditions 2 If the person takes medicine the pressure will vary more 3 Wait at least 3 minutes for another measurement Why do I get a...

Страница 13: ...r assistance Refer to the warranty for contact information and return instructions Power supply Display mode Measurement mode Oscillographic testing mode Measurement range Accuracy Normal working cond...

Страница 14: ...or basic safety and essential performance Collateral standard Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment IEC EN 60601 1 2 2007...

Страница 15: ...buildings used for domestic purposes Guidance and manufacturer s declaration electromagnetic immunity IMMUNITY test 6 kV contact 8 kV air 6 kV contact 8 kV air 2 kV for power supply lines Not applicab...

Страница 16: ...fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the device is used exceeds the applicable RF compliance level above th...