background image

4

General information

5

Component part and accessories

1.  Main unit – P08/P12/P15/P20/P30
2.  Installation accessories

• 

Installation instructions

• 

Union couplings

• 

Damping rubber blocks

• 

Drainage pipe

• 

Winter cover

Important information

Especially important points concerning transport and 

storage, installation, usage, maintenance and fault tracing are 

presented below.

 

Transport and storage

Models designed to be transported vertically must be 

transported in this way. This is because the suspension inside 

the compressor can be damaged if the unit is laid down. If 

the heat pump is tilted during installation or draining this 

should be done with care and for the shortest time possible.

The original packaging is intended to be used to reduce the 

risk of transport damage.

Remove the packaging and before installation check that the 

heat pump has not been damaged during transport. Report 

any transport damage to the forwarding agent.

Installation

The pool heat pump must be installed by a qualified 

installation engineer and placed outdoors. The unit must 

stand firmly, straight and raised from ground level. Provide a 

firm and flat surface, for example, garden slabs, concrete bed, 

Leca blocks or similar.

Noise propagation must be taken into consideration when 

positioning during installation. Positioning of the unit must 

be done so that noise from the compressor and fan disturb 

the environment as little as possible.

Large amounts of melt and condensation water can be 

discharged during defrosting and operation. Consequently, it 

is important to provide good drainage and run-off.

The units must stand freely so that air is not prevented to 

pass the evaporator. Avoid a placement that produces cold 

air circulation as this reduces the output of the heat pump.

Use and operation

The parameters on the display are set at the factory and do 

not need to be adjusted. The temperature is set to 27 °C. If 

you wish to increase the temperature, check first to ensure 

that your wishes of a high temperature do not contravene 

any guarantees concerning the general pool construction.

Maintenance procedures

It is important to drain the water from the pool heat 

pump before the winter. The material guarantee does not 

cover damage due to freezing on account of insufficient 

maintenance. The heat exchanger can also be flushed out to 

remove any remaining deposits ahead of winter drainage. 

Read more about drainage in section 4 - Maintenance, service 

and fault tracing.

Perform regular checks to ensure that the inlet grille is not 

blocked by leaves, snow, etc. In addition, make sure that 

excessive frost or ice does not build up below the unit during 

cold weather conditions.

The outer case can be cleaned using a damp cloth if 

necessary. Take care not to scratch the unit.

Service and support

The pool heat pump is designed for reliable operation and a 

long life. If a fault should occur you should always contact the 

installation engineer who carried out the installation. If the 

installation engineer in turn considers it to be a question of 

a material or manufacturing fault, he/she will contact us for 

inspection and action to rectify the problem. Always state the 

product’s manufacturing number. The number can be found 

on the rating plate below the LED display. A basic guide to 

fault tracing is presented in section 4 - Maintenance, service 

and fault tracing.

Installation material is enclosed inside the 

machine. Open the cover and remove the 

material before installation. Note that the 

installation engineer provides pipes and the 

bypass coupling for the installation.

!

Содержание P08

Страница 1: ...Installation and Maintenance guide P08 P12 P15 P20 P30 EN ________________________________________________________________________________________________ Rev 2015 1 ...

Страница 2: ...ld responsible for damage resulting from incorrect installation incorrect fault tracing or incorrect maintenance Yours sincerely Gullberg Jansson AB Subject to possible misprints and design alterations Gullberg Jansson AB is not responsible for misinterpretations any obvious misprints and consequences resulting from these FOR YOUR OWN RECORDS Please complete the details below Keep these close to h...

Страница 3: ...t 7 Set up 7 Distance to the pool 8 Leading off condensation water 8 Pipe connections 8 Bypass coupling 8 Parallel coupling of several units 8 Electrical installation 9 Starting up the unit 9 Use and operation Description of LED controls 10 How to change operating parameters 10 How you select the operating mode 11 Checking sensor values 11 Maintenance service and fault tracing Winter drainage 12 M...

Страница 4: ...efficiency during different parts of the year depending on the outdoor conditions At the start of the season when the water in the pool is cold the heat pump needs to work continuously for a long period to produce the right temperature in the pool When the pool water has reached the required temperature the heat pump automatically stops and starts as required It is always cost effective to cover t...

Страница 5: ...that produces cold air circulation as this reduces the output of the heat pump Use and operation The parameters on the display are set at the factory and do not need to be adjusted The temperature is set to 27 C If you wish to increase the temperature check first to ensure that your wishes of a high temperature do not contravene any guarantees concerning the general pool construction Maintenance p...

Страница 6: ...led correctly Mount the heat pump after the sand filter 5 5 Install a bypass with three ball valves to regulate the right partial flow in case the flow exceeds the recommended working volume for the pool heat pump 5 5 Connect the electricity 5 5 Operating mode Check carefully to ensure there is sufficient circulation before start up 5 5 Adjust the flow to the pool heat pump to the right level 5 5 ...

Страница 7: ...l heat pump must be placed on a firm horizontal base and should not be placed next to or be installed with brackets on sensitive walls with a lightweight structure The unit must be placed so that noise from the compressor and fan disturb the surroundings as little as possible The unit must stand firmly straight and raised from ground level Ensure a firm and flat surface is provided for example gar...

Страница 8: ... Bypass coupling We recommend that a bypass coupling is fitted to all installations in order to adjust the right partial flow to the pool heat pump The right partial flow results in balanced operation and reduced wear on the heat pump s most expensive section the heat exchanger Adjusting the bypass Correct adjust of the bypass can be done in different ways One of the easiest ways can be summarized...

Страница 9: ...changer The following procedure should be followed when starting the pool heat pump for the first time 1 Start the pool s circulation pump Check for any leakage and that there is a flow to and from the pool 2 Switch on the supply voltage press ON OFF on the display the unit should start after a few seconds 3 After a few minutes check that the exhaust air is colder than the outdoor air temperature ...

Страница 10: ...arameters 2 9 How to change operating parameters 1 Shut down the unit by pressing in the knob 2 Select the parameter between 0 9 by rotating the knob 3 Press in the knob 4 When the parameter value flashes the setting can be made by rotating the knob 5 The parameter value stops flashing after 5 seconds and the setting is accepted Press in the knob to start stop the heat pump Press and hold the knob...

Страница 11: ...s the inlet temp and the operating mode during normal operations 2 If parameter 8 is set to 1 it is possible to switch between cooling and heating modes by pressing and holding the knob for 5 seconds and then rotate the knob between HEAT and COOL Operating mode set to cooling How you select the operating mode Operating mode set to heating Checking sensor values Inlet temperature Temperature of the...

Страница 12: ...urn considers it to be a question of a material or manufacturing fault he she will contact us for inspection and action to rectify the problem Always state the product s manufacturing number Information can be gained from the following fault tracing guide Frequently asked questions with answers are also presented in the section 6 Always read through this section before contacting your dealer Opera...

Страница 13: ...ode as set out in the section 4 3 Larger heat pump required 4 The season is over Larger heat pump required 5 The pool needs to be covered The heat pump ices up again 1 Pool temperature is too low 2 High humidity 1 Reset parameters for defrosting to a longer defrosting time If necessary run in cooling mode to melt the ice See section 4 2 Reset parameters for defrosting to a higher stop temp If nece...

Страница 14: ... pressure pressostat signal digital input 12 DI04 GND High pressure pressostat signal digital input 13 DI05 GND Mode input digital input 14 DI06 GND Sensor terminal not used digital input 15 AI01 GND Sensor terminal not used analogue input 16 AI02 GND Incoming water temperature analogue input 17 AI03 GND Outgoing water temperature analogue input 18 AI04 GND Evaporator coil temperature analogue inp...

Страница 15: ...M1 K1 KM1 230V OUT1 OUT2 OUT3 OUT4 AC N 1 2 3 4 CN19 GND AI06 GND AI05 GND AI04 GND AI03 CN1 CN2 12V NET GND DI01 GND DI02 GND DI03 GND DI04 GND DI05 GND PC1001 GND AI02 OUT5 CN6 GND AI01 DI06 GND CN16 HL Only for P08 P12 P15 Only for P20 P30 AT Ambient temperature COMP Compressor CT Evaporator temperature FM Fan motor IT Inlet water temperature LP Low pressure switch OT Outlet water temperature 4...

Страница 16: ...47 51 54 Water connection mm 32 mm 50 mm Rated water flow m3 h 1 5 1 8 2 2 3 0 4 5 Pressure drop at rated flow bar 0 12 0 12 0 08 0 10 0 10 Pressostat breaking value HP bar 44 closes again at 32 bar Pressostat breaking value LP bar 0 2 closes again at 1 5 bar Height mm 560 560 570 650 650 Width mm 970 970 746 1053 1053 Depth mm 350 350 290 445 445 Weight kg 31 37 38 55 58 1 Heating output measured...

Отзывы: