background image

Installation and Maintenance guide

P08/P12/P15/P20/P30

EN

________________________________________________________________________________________________

Rev. 2015.1

Содержание P08

Страница 1: ...Installation and Maintenance guide P08 P12 P15 P20 P30 EN ________________________________________________________________________________________________ Rev 2015 1 ...

Страница 2: ...ld responsible for damage resulting from incorrect installation incorrect fault tracing or incorrect maintenance Yours sincerely Gullberg Jansson AB Subject to possible misprints and design alterations Gullberg Jansson AB is not responsible for misinterpretations any obvious misprints and consequences resulting from these FOR YOUR OWN RECORDS Please complete the details below Keep these close to h...

Страница 3: ...t 7 Set up 7 Distance to the pool 8 Leading off condensation water 8 Pipe connections 8 Bypass coupling 8 Parallel coupling of several units 8 Electrical installation 9 Starting up the unit 9 Use and operation Description of LED controls 10 How to change operating parameters 10 How you select the operating mode 11 Checking sensor values 11 Maintenance service and fault tracing Winter drainage 12 M...

Страница 4: ...efficiency during different parts of the year depending on the outdoor conditions At the start of the season when the water in the pool is cold the heat pump needs to work continuously for a long period to produce the right temperature in the pool When the pool water has reached the required temperature the heat pump automatically stops and starts as required It is always cost effective to cover t...

Страница 5: ...that produces cold air circulation as this reduces the output of the heat pump Use and operation The parameters on the display are set at the factory and do not need to be adjusted The temperature is set to 27 C If you wish to increase the temperature check first to ensure that your wishes of a high temperature do not contravene any guarantees concerning the general pool construction Maintenance p...

Страница 6: ...led correctly Mount the heat pump after the sand filter 5 5 Install a bypass with three ball valves to regulate the right partial flow in case the flow exceeds the recommended working volume for the pool heat pump 5 5 Connect the electricity 5 5 Operating mode Check carefully to ensure there is sufficient circulation before start up 5 5 Adjust the flow to the pool heat pump to the right level 5 5 ...

Страница 7: ...l heat pump must be placed on a firm horizontal base and should not be placed next to or be installed with brackets on sensitive walls with a lightweight structure The unit must be placed so that noise from the compressor and fan disturb the surroundings as little as possible The unit must stand firmly straight and raised from ground level Ensure a firm and flat surface is provided for example gar...

Страница 8: ... Bypass coupling We recommend that a bypass coupling is fitted to all installations in order to adjust the right partial flow to the pool heat pump The right partial flow results in balanced operation and reduced wear on the heat pump s most expensive section the heat exchanger Adjusting the bypass Correct adjust of the bypass can be done in different ways One of the easiest ways can be summarized...

Страница 9: ...changer The following procedure should be followed when starting the pool heat pump for the first time 1 Start the pool s circulation pump Check for any leakage and that there is a flow to and from the pool 2 Switch on the supply voltage press ON OFF on the display the unit should start after a few seconds 3 After a few minutes check that the exhaust air is colder than the outdoor air temperature ...

Страница 10: ...arameters 2 9 How to change operating parameters 1 Shut down the unit by pressing in the knob 2 Select the parameter between 0 9 by rotating the knob 3 Press in the knob 4 When the parameter value flashes the setting can be made by rotating the knob 5 The parameter value stops flashing after 5 seconds and the setting is accepted Press in the knob to start stop the heat pump Press and hold the knob...

Страница 11: ...s the inlet temp and the operating mode during normal operations 2 If parameter 8 is set to 1 it is possible to switch between cooling and heating modes by pressing and holding the knob for 5 seconds and then rotate the knob between HEAT and COOL Operating mode set to cooling How you select the operating mode Operating mode set to heating Checking sensor values Inlet temperature Temperature of the...

Страница 12: ...urn considers it to be a question of a material or manufacturing fault he she will contact us for inspection and action to rectify the problem Always state the product s manufacturing number Information can be gained from the following fault tracing guide Frequently asked questions with answers are also presented in the section 6 Always read through this section before contacting your dealer Opera...

Страница 13: ...ode as set out in the section 4 3 Larger heat pump required 4 The season is over Larger heat pump required 5 The pool needs to be covered The heat pump ices up again 1 Pool temperature is too low 2 High humidity 1 Reset parameters for defrosting to a longer defrosting time If necessary run in cooling mode to melt the ice See section 4 2 Reset parameters for defrosting to a higher stop temp If nece...

Страница 14: ... pressure pressostat signal digital input 12 DI04 GND High pressure pressostat signal digital input 13 DI05 GND Mode input digital input 14 DI06 GND Sensor terminal not used digital input 15 AI01 GND Sensor terminal not used analogue input 16 AI02 GND Incoming water temperature analogue input 17 AI03 GND Outgoing water temperature analogue input 18 AI04 GND Evaporator coil temperature analogue inp...

Страница 15: ...M1 K1 KM1 230V OUT1 OUT2 OUT3 OUT4 AC N 1 2 3 4 CN19 GND AI06 GND AI05 GND AI04 GND AI03 CN1 CN2 12V NET GND DI01 GND DI02 GND DI03 GND DI04 GND DI05 GND PC1001 GND AI02 OUT5 CN6 GND AI01 DI06 GND CN16 HL Only for P08 P12 P15 Only for P20 P30 AT Ambient temperature COMP Compressor CT Evaporator temperature FM Fan motor IT Inlet water temperature LP Low pressure switch OT Outlet water temperature 4...

Страница 16: ...47 51 54 Water connection mm 32 mm 50 mm Rated water flow m3 h 1 5 1 8 2 2 3 0 4 5 Pressure drop at rated flow bar 0 12 0 12 0 08 0 10 0 10 Pressostat breaking value HP bar 44 closes again at 32 bar Pressostat breaking value LP bar 0 2 closes again at 1 5 bar Height mm 560 560 570 650 650 Width mm 970 970 746 1053 1053 Depth mm 350 350 290 445 445 Weight kg 31 37 38 55 58 1 Heating output measured...

Отзывы: