background image

 

Section 5

 

 

TM9340-G-00 
15 August, 2019 

5-1 

5.  PARTS LISTS 

Model 

General Assembly 

Parts List 

 

Model 

General Assembly 

Parts List 

9343/10 

18680.01.02-PL 

 

  9344/100 

18697.01.02-PL 

  9343/100 

18680.02.02-PL 

 

  9344/1k 

18697.02.02-PL 

  9343/1k 

18680.03.02-PL 

 

  9344/10k 

18697.03.02-PL 

  9343/10k 

18680.04.02-PL 

 

  9344/100k 

18697.04.02-PL 

  9343/100k 

18680.05.02-PL 

 

  9344/1M 

18697.05.02-PL 

  9343/1M 

18680.06.02-PL 

 

  9344/10M 

18697.06.02-PL 

  9343/10M 

18680.07.02-PL 

 

  9344/100M 

18697.07.02-PL 

  9343/100M 

18680.08.02-PL 

 

  9344/1G 

18697.08.02-PL 

  9343/1G 

18680.09.02-PL 

 

  9344/10G 

18697.09.02-Pl 

  9343/10G 

18680.10.02-PL 

 

  9344/100G 

18697.10.02-PL 

  9343/100G 

18680.11.02-PL 

 

  9344/1T 

18697.11.02-PL 

  9343/1T 

18680.12.02-PL 

 

  9344/10T 

18697.12.02-PL 

  9343/10T 

18680.13.02-PL 

 

 

 

 

 

 

 

 

  9345/1k 

18630.01.02-PL 

 

  9346/10k 

18660.01.02-PL 

  9345/10k 

18630.02.02-PL 

 

  9346/100k 

18660.02.02-PL 

  9345/100k 

18630.03.02-PL 

 

  9346/1M 

18660.03.02-PL 

  9345/1M 

18630.04.02-PL 

 

  9346/10M 

18660.04.02-PL 

  9345/10M 

18630.05.02-PL 

 

  9346/100M 

18660.05.02-PL 

  9345/100M 

18630.06.02-PL 

 

  9346/1G 

18660.06.02-PL 

  9345/1G 

18630.07.02-PL 

 

  9346/10G 

18660.07.02-PL 

  9345/10G 

18630.08.02-PL 

 

  9346/100G 

18660.08.02-PL 

  9345/100G 

18630.09.02-PL 

 

  9346/1T 

18660.09.02-PL 

  9345/1T 

18630.10.02-PL 

 

  9346/10T 

18660.10.02-PL 

  9345/10T 

18630.11.02-PL 

 

 

 

 

 

 

 

 

  9347/100k 

18656.01.02-PL 

 

 

 

  9347/1M 

18656.02.02-PL 

 

 

 

  9347/10M 

18656.03.02-PL 

 

 

 

  9347/100M 

18656.04.02-PL 

 

 

 

  9347/1G 

18656.05.02-PL 

 

 

 

  9347/10G 

18656.06.02-PL 

 

 

 

  9347/100G 

18656.07.02-PL 

 

 

 

  9347/1T 

18656.08.02-PL 

 

 

 

  9347/10T 

18656.09.02-PL 

 

 

 

 

 

 

 

 

Table 5-1: General Assembly Parts Lists

 

Содержание 9340 Series

Страница 1: ...prietary to Guildline Instruments Limited They are to be used only as a guide to the operation and maintenance of the equipment with which this manual was issued and may not be duplicated or transmitt...

Страница 2: ...NAL DESCRIPTION 1 1 1 2 FEATURES 1 2 1 3 GENERAL THEORY 1 2 2 SPECIFICATIONS 2 1 3 RECEIPT AND INSPECTION 3 1 3 1 GENERAL 3 1 3 2 PACKAGING 3 1 4 OPERATION AND MAINTENANCE 4 1 4 1 OPERATION 4 1 4 2 MA...

Страница 3: ...TM9340 G 00 15 August 2019 ii TABLE OF FIGURES FIGURE 1 1 9340 SERIES OF RESISTANCE DECADE BOXES 1 1 FIGURE 1 2 DECADE BOX SCHEMATIC DIAGRAM 1 2...

Страница 4: ...TM9340 G 00 15 August 2019 iii LIST OF TABLES TABLE 2 1 MODEL SELECTION TABLE 2 2 TABLE 2 2 MODEL SPECIFICATIONS 2 4 TABLE 5 1 GENERAL ASSEMBLY PARTS LISTS 5 1...

Страница 5: ...niques established at Guildline in the construction and stabilizing of resistors and low uncertainty switching techniques used in many of our instruments The Model 9340 Series is available in decade r...

Страница 6: ...resistors switched in a series circuit Figure 1 1 illustrates schematically the circuit of the Model 9347 The Models 9343 9344 9345 9346 and 9347 are identical except for the number of decades The val...

Страница 7: ...0 001 ohm per decade after settling Breakdown Voltage 1500 Volts to case Dimensions 9343 11 8cm X 23 3cm X 10 3cm high 9344 11 8cm X 29 0cm X 10 3cm high 9345 11 8cm X 34 7cm X 10 3cm high 9346 11 8cm...

Страница 8: ...343 10G 3 10M 11 10 G 9344 100G 4 10M 111 1 G 9343 100G 3 100M 111 0 G 9344 1T 4 100M 1 111 T 9343 1T 3 1G 1 110T 9344 10T 4 1G 11 11 T 9343 10T 3 10G 11 10 T Model Number of Decades Minimum Step s Ma...

Страница 9: ...nimum Step s Maximum Value s 9347 100k 7 0 01 111 111 1 k 9347 1M 7 0 1 1 111 111 M 9347 10M 7 1 11 111 11 M 9347 100M 7 10 111 111 1 M 9347 1G 7 100 1 111 111 G 9347 10G 7 1k 11 111 11 G 9347 100G 7...

Страница 10: ...0 2 0 5 7 0 07 0 1 1 50 5 0 2 0 5 2 0 2 1 10 20 5 0 2 0 5 0 7 0 7 10 100 10 5 0 2 0 5 0 2 2 100 1 k 10 5 0 2 0 5 0 07 7 1 k 10 k 10 5 0 2 0 5 0 02 20 10 k 100 k 10 5 0 2 0 5 0 007 70 100 k 1 M 10 5 0...

Страница 11: ...ince the 1k Dial set to 7 Position is most significant dial used the accuracy would be 0 01 2 m for all the 9340 Dial Settings for the entire resistance output Example 2 A 9346 100M Decade Standard is...

Страница 12: ...mechanical damage when received Nevertheless you should perform an inspection for physical damage ensure all items on the packing list are present and test the instrument electrically as soon as poss...

Страница 13: ...al Multimeter with a minimum accuracy specification of better than 20 ppm over the range of 1 to 10 M A suitably accurate Teraohometer is required for models with resistance ranges above 1 G 4 3 REPAI...

Страница 14: ...11 02 PL 9343 1T 18680 12 02 PL 9344 10T 18697 12 02 PL 9343 10T 18680 13 02 PL 9345 1k 18630 01 02 PL 9346 10k 18660 01 02 PL 9345 10k 18630 02 02 PL 9346 100k 18660 02 02 PL 9345 100k 18630 03 02 P...

Страница 15: ...75 03 02 PL 10 Decade 18675 04 02 PL 100 Decade 18675 05 02 PL 1k Decade 18675 06 02 PL 10 k Decade 18675 07 02 PL 100 k Decade 18675 08 02 PL 1 M Decade 18675 09 02 PL 10 M Decade 18675 10 02 PL 100...

Страница 16: ...NGS Decade Box Drawing 9343 Decade Box General Assembly 18680 01 02 9344 Decade Box General Assembly 18697 01 02 9345 Decade Box General Assembly 18630 01 02 9346 Decade Box General Assembly 18660 01...

Отзывы: