Operating Responders
55
The responder must always be used with its longest side vertical,
and its carrying handle at the top.
Switch the unit off when not in use to preserve the battery.
!
The responder is water resistant.
However, do not submerge the unit in water.
To Switch the Responder ON:
•
Press the
ON/OFF
button at the top of the unit.
•
For a rechargeable responder, the
green
light in the centre of the
button indicates how much battery charge is remaining (assuming
24/7 operation):
Light solidly on
Up to 22 days left
1 flash in 5 seconds
Up to 10 days left
3 flashes in 5 seconds
Up to 1 day left
•
For a mains powered responder, the light should flash with an
interval of 5 seconds.
•
For a primary cell responder, the light indicates the state of the
primary cell pack:
1 flash in 5 seconds
PCP normal
3 flashes in 5 seconds
PCP low
Under normal conditions, the primary cell responder will operate for up
to one year before the batteries need replacing.
!
When a rechargeable responder is switched on and the green
light is not illuminated, recharge the battery.
!
When a primary cell responder is switched on and the
green light does not flash at all, replace the whole primary
cell. Alternatively, the batteries within the primary cell may
be replaced, but this must only be done in an ATEX safe
environment, using batteries supplied by Guidance Marine or
authorised partners.
ON/OFF Button