Fig. 4
If the generator is not working after several starting
attempts, the oil pipeline must be manually blown
through.
GSE 5500 DSG (#40586) Generator Turning Off
Fig. 5
Disconnect the appliance from the unit before
stopping the engine.
Close the fuel tap (OFF).
Turn the fuel cock in (OFF) position.
CAUTION!
Always pill the key from the unit
when the generator is out of use and keep it at a
safe place. If the engine is not used for a longer
period of time, it must be switched off, too.
Operator Safety Instructions
See General Safety Instructions and Initial Operation Safety Instructions.
Do not use the machine until you have read the instruction manual carefully.
Observe any safety instructions included in the manual.
Be responsible to the others
Troubles – Causes – Troubleshooting
Trouble Cause
Troubleshooting
The engine will not
start up.
1.
Fuel cock closed
2. No
fuel
3.
Too little oil in the tank
4.
Air in oil pipeline
5. Battery
too
weak
1.
Make sure that the fuel cock on/off switch are in on position
2.
Make sure that there is enough fuel in the tank.
3.
Replenish the oil
4.
Have the oil pipeline blown through
5.
Charge the battery with appropriate charger
Engine runs unevenly
1. Poor
fuel
2.
Air in oil pipeline
1.
Make sure that the used fuel is correct.
2.
Have the oil pipeline blown through
No current from
generator.
Short circuit
Defective
cable
Loose
cable
1.
If the light indicator is off, the defect is impossible to be
cleared by yourself. .
If the light indicator is on :
2.
Press the overloading protection for the required output.
3.
Check the connection.
4.
Check whether a short circuit or overloading is not the
cause.
75
18