Gude 85027 Скачать руководство пользователя страница 5

 

Behaviour in case of emergency 

 
Provide necessary first aid treatment corresponding to the 
injury nature and seek qualified medical help as soon as 
possible.  
Protect the injured person from other injuries and calm 
him/her down. 
 

First aid kit must always be available in the place of 
your work in case of accident in accordance with DIN 
13164. Material taken out of the first aid kit needs to be 
supplemented right away. 
If help is needed,  
 
please provide the following details: 
 
1. Place 

of 

accident 

2. Accident 

nature 

3. 

Number of injured persons 

4. Injury 

type 

 
The designed purpose of use of the device 

 

 

Catalytic heater for bottled gas heating in well 
ventilated rooms (with minimum capacity of 40m³) 

 

 

Any other use is in conflict with the designed 

purpose!  

 

Technical data 

 

Maximum output 

3000 W 

Consumption: 

220 g/h 

Nominal connection pressure:  50 mbar 
Gas: Propan/Butan 
Weight: 14 

kg 

 

Disposal 

 
The disposal instructions are based on icons placed on the 
appliance or its package. The description of the meanings 
can be found in the “Marking” chapter. 

 
Transport package disposal

 

The package protects the appliance against damage 
during transport. Packing materials are usually chosen 
depending on their environmental friendliness and 
disposal method and can therefore be recycled.  
Returning the package to material circulation saves raw 
materials and reduces waste disposal costs.  
Parts of packages (e.g. foils, styropor) can be dangerous 
to children. 

Risk of suffocation!

  

Keep parts of packages away from children and dispose 
them as soon as possible 
 

Operating staff requirements 

 
The operator must carefully read the Operating 
Instructions before using the appliance. 
 

Qualification 

 
No special qualification is necessary for using the 
appliance apart from detailed instruction by a qualified 
person. 
 

Minimum age 

 
The appliance may only be operated by persons over 16 
years of age. An exception includes youngsters operating 
the appliance within their professional education to 
achieve necessary skills under teacher's supervision. 
 
 
 
 

Training 

 
Using the appliance only requires appropriate instructions 
by a professional or reading the Operating Instructions. No 
special training necessary. 
 

Installation / first use 

 
This appliance is equipped with a 

40 cm gas hose for 

connection

 – to ensure correct functioning, 

a pressure 

regulator for 50 mbar on the cylinder 

is absolutely 

necessary. We recommend the following pressure 
regulators according to the purpose of use: 

 

  Leisure time use – e.g. terrace, outdoors space, tent 

vestibule, party tents etc., with adequate air in-take 
and exhaust, 

pressure regulator

 

50 mbar 

  For home use (any in-doors spaces) in compliance 

with TRF1996-5.2.7.2 (amendment valid from the 1

st

 of 

June 2000) and for all industrial liquid-gas devices 
(indoors and outdoors) in compliance with UW BGV 
D34 section 11 par. 3 and 4: 

two-stage safety 

pressure regulator ,,t" 50 mbar with pressure 
gauge  (not included).

 

 

Installation of the back cover - illustration 1: 

To install the back cover, follow steps A, B and C: 

Turn the gas cylinder around until the opening points 
outwards, to provide good access to the gas valve.   

Make sure the base of the gas cylinder is positioned 
between the wheels support holder cubes. 

 

Install the back cover by placing the four hooks into 
the openings in the protective cover. 

 

 
Installation of the bottom - illustration 2: 

(1) 

Take out the 

plastic button (E). Both cocks (C) of 

the bottom part (B) 

must be fully inserted into the 

back openings of the 

bottom (A) 

in the

 

relevant 

hollows

 

(D)

.

 

(2) Place 

the plastic button (E)

 you took out earlier into 

both bottom openings 

(A) 

and 

(B)

 

Safety instructions – operation  
 

General instructions for liquid gas cylinders handling: 

Characteristics of liquid gas: 

The liquid gas (propane, butane and their mixes) is a 
highly flammable, colourless gas with strong smell. It is 
heavier than air and it is flammable when mixed with even 
a small amount of air.  

 

Warning! Gas leaking without control can burst 

into flame or explode.  

The liquid gas in the cylinder is pressurized. Protect it from 
temperatures over 40°C! Higher temperature, especially 
due to fire, causes risk of uncontrolled gas leak and even 
an explosion of the cylinder.   
 

Malfunction procedure: 

In case of malfunction and leaks (e.g. smell of gas, sounds 
produced by leaking) follow these rules and guidelines: 

 

Turn the cylinder valve off immediately (clockwise). 

 

Do not smoke and no not use open fire.  

 

Do not turn any electric switch on or off. 

 

Do not make phone calls. 

 

Open doors and windows, ensure ventilation.  

 

If possible, carry the leaking cylinder outside of the 
building.  

 

Leave the building and advise technical help of the 
situation.  

 

 
 

Содержание 85027

Страница 1: ...3000 85027 Güde GmbH Co KG Birkichstrasse 6 D 74549 Wolpertshausen Deutschland English GB Translation of original operating instructions CATALYTIC HEATER English ...

Страница 2: ...Gas cylinder base Wheels support holder cubes 1 2 8 ...

Страница 3: ...sheet metal for an even heat output Not suitable for bathrooms bedrooms or as a permanent heating device in living spaces EU DECLARATION OF COMPLIANCE We Güde GmbH Co KG Birkichstrasse 6 D 74549 Wolpertshausen Germany herewith declare that the following appliance complies with the appropriate basic safety and health requirements of the EU Directives based on its design and type as brought into cir...

Страница 4: ...s without the necessary technical knowledge It is absolutely necessary to know the regulations and directives for accident prevention valid in the place of operation as well as the other general safety rules This tool complies with all appropriate safety regulations Repairs can be performed only by qualified electricians in authorized service shops using only the original spare parts Non complianc...

Страница 5: ...liance is equipped with a 40 cm gas hose for connection to ensure correct functioning a pressure regulator for 50 mbar on the cylinder is absolutely necessary We recommend the following pressure regulators according to the purpose of use Leisure time use e g terrace outdoors space tent vestibule party tents etc with adequate air in take and exhaust pressure regulator 50 mbar For home use any in do...

Страница 6: ... 5 years at the latest Connection of the liquid gas cylinder Take the protective cover of the valve off Take the covering nut from the attachment socket off by turning right Check the rubber seal in the cylinder valve regulator connection The regulator and the hose must be screwed on tightly left thread No not use any tool or instrument Do not turn the regulator but the sleeve nut Check the tightn...

Страница 7: ...asive cleaning means or solvents for cleaning In case of a longer discontinuation of use disconnect the gas cylinder and place it outside of the device store the device in a dust free environment Contact your contractual sales point for more extensive maintenance Use only original spare parts for repairs Such maintenance should be performed at least once every 2 to 3 years 13 ...

Отзывы: