58
Expert Power Control 8031/8035
© 2021 GUDE Systems GmbH
Specifications
settable
Resettable Forward Reactive Energy counter.
epc8031RevEnergyActive
.81.1.5.1.2.1.20.x
Gauge32
RO
Reverse Active Energy counter.
epc8031RevEnergyReactive
.81.1.5.1.2.1.21.x
Gauge32
RO
Reverse Reactive Energy counter.
epc8031RevEnergyActiveReset-
table
.81.1.5.1.2.1.22.x
Gauge32
RO
Resettable Reverse Active Energy counter.
epc8031RevEnergyReactiveReset-
table
.81.1.5.1.2.1.23.x
Gauge32
RO
Resettable Reverse Reactive Energy counter.
epc8031ResidualCurrent
.81.1.5.1.2.1.24.x
Unsigned32
RO
Actual Residual Current on Power Channel. According Type A IEC
60755. Only visible on models that support this feature.
epc8031ResidualCurrentRMS
.81.1.5.1.2.1.25.x
Unsigned32
RO
Actual Residual Current RMS on Power Channel. According Type B IEC
60755. Only visible on models that support this feature.
epc8031ResidualCurrentDC
.81.1.5.1.2.1.26.x
Unsigned32
RO
Actual Residual Current DC on Power Channel. According Type B IEC
60755. Only visible on models that support this feature.
epc8031LineSensorName
.81.1.5.1.2.1.100.x
OCTETS
RW
A textual string containing name of a Line Sensor
epc8031OVPIndex
.81.1.5.2.1.1.x
Integer32
RO
None
epc8031OVPStatus
.81.1.5.2.1.2.x
INTEGER
RO
shows the status of the built-in Overvoltage Protection
epc8031CPUSensorVsystem
.81.1.5.14.1.0
Gauge32
RO
System Voltage on CPU Board
epc8031CPUSensorVaux
.81.1.5.14.2.0
Gauge32
RO
Auxiliary Voltage on CPU Board
epc8031CPUSensorVmain
.81.1.5.14.3.0
Gauge32
RO
Main Voltage on CPU Board
epc8031CPUSensorTcpu
.81.1.5.14.4.0
Integer32
RO
Temperature on CPU Board
epc8031NTPTimeValid
.81.1.5.15.1.0
INTEGER
RO
Show if valid Time is received
epc8031NTPUnixTime
.81.1.5.15.2.0
Unsigned32
RO
show received NTP time as unixtime (secs since 1 January 1970)
epc8031NTPLastValidTimestamp
.81.1.5.15.3.0
Unsigned32
RO
show seconds since last valid NTP timestamp received
epc8031SensorIndex
.81.1.6.1.1.1.x
Integer32
RO
None
epc8031TempSensor
.81.1.6.1.1.2.x
Integer32
RO
actual temperature
epc8031HygroSensor
.81.1.6.1.1.3.x
Integer32
RO
actual humidity
epc8031AirPressure
.81.1.6.1.1.5.x
Integer32
RO
actual air pressure
epc8031DewPoint
.81.1.6.1.1.6.x
Integer32
RO
dew point for actual temperature and humidity
epc8031DewPointDiff
.81.1.6.1.1.7.x
Integer32
RO
difference between dew point and actual temperature (Temp -
DewPoint)
epc8031ExtSensorName
.81.1.6.1.1.32.x
OCTETS
RW
A textual string containing name of a external Sensor
4.5.2
Device MIB 8035
Below is a table of all device-specific OID 's which can be accessed via SNMP. In the
numerical representation of the OID the prefix " 1.3.6.1.4.1.28507 " (Gude Enterprise
OID) was omitted at each entry in the table to preserve space. The example for a com-
plete OID would be "1.3.6.1.4.1.28507.83.1.1.1.1". A distinction is made in SNMP OID
's in between tables and scalars. OID scalar have the extension ".0" and only specify a
value. In SNMP tables the "x" is replaced by an index (1 or greater) to address a value
from the table.
Name
OID
Type
Acc.
Description
epc8035TrapCtrl
.83.1.1.1.1.0
Integer32
RW