Specifications
epc8001spPow erReactive
.100.1.5.5.2.1.11.x
Integer32
RO
L Line Mean Reactive Pow er
epc8001spAbsEnergyReactive
.100.1.5.5.2.1.12.x
Gauge32
RO
Absolute Reactive Energy counter.
epc8001spAbsEnergyActiveReset
table
.100.1.5.5.2.1.13.x
Gauge32
RW
Resettable Absolute Active Energy counter. Writing '0' resets all
resettable counter.
epc8001spAbsEnergyReactiveRe
settable
.100.1.5.5.2.1.14.x
Gauge32
RO
Resettable Absolute Reactive Energy counter.
epc8001spResetTime
.100.1.5.5.2.1.15.x
Gauge32
RO
Time in seconds since last Energy Counter reset.
epc8001spForw EnergyActive
.100.1.5.5.2.1.16.x
Gauge32
RO
Forw ard Active Energy counter.
epc8001spForw EnergyReactive
.100.1.5.5.2.1.17.x
Gauge32
RO
Forw ard Reactive Energy counter.
epc8001spForw EnergyActiveRes
ettable
.100.1.5.5.2.1.18.x
Gauge32
RO
Resettable Forw ard Active Energy counter.
epc8001spForw EnergyReactiveR
esettable
.100.1.5.5.2.1.19.x
Gauge32
RO
Resettable Forw ard Reactive Energy counter.
epc8001spRevEnergyActive
.100.1.5.5.2.1.20.x
Gauge32
RO
Reverse Active Energy counter.
epc8001spRevEnergyReactive
.100.1.5.5.2.1.21.x
Gauge32
RO
Reverse Reactive Energy counter.
epc8001spRevEnergyActiveReset
table
.100.1.5.5.2.1.22.x
Gauge32
RO
Resettable Reverse Active Energy counter.
epc8001spRevEnergyReactiveRes
ettable
.100.1.5.5.2.1.23.x
Gauge32
RO
Resettable Reverse Reactive Energy counter.
epc8001CPUSensorVsystem
.100.1.5.14.1.0
Gauge32
RO
System Voltage on CPU Board
epc8001CPUSensorVaux
.100.1.5.14.2.0
Gauge32
RO
Auxiliary Voltage on CPU Board
epc8001CPUSensorVmain
.100.1.5.14.3.0
Gauge32
RO
Main Voltage on CPU Board
epc8001CPUSensorTcpu
.100.1.5.14.4.0
Integer32
RO
Temperature on CPU Board
epc8001NTPTimeValid
.100.1.5.15.1.0
INTEGER
RO
Show if valid Time is received
epc8001NTPUnixTime
.100.1.5.15.2.0
Unsigned32
RO
show received NTP time as unixtime (secs since 1 January 1970)
epc8001NTPLastValidTimestamp
.100.1.5.15.3.0
Unsigned32
RO
show seconds since last valid NTP timestamp received
epc8001SensorIndex
.100.1.6.1.1.1.x
Integer32
RO
None
epc8001TempSensor
.100.1.6.1.1.2.x
Integer32
RO
actual temperature
epc8001HygroSensor
.100.1.6.1.1.3.x
Integer32
RO
actual humidity
epc8001AirPressure
.100.1.6.1.1.5.x
Integer32
RO
actual air pressure
epc8001Dew Point
.100.1.6.1.1.6.x
Integer32
RO
dew point for actual temperature and humidity
epc8001Dew PointDiff
.100.1.6.1.1.7.x
Integer32
RO
difference betw een dew point and actual temperature (Temp -
Dew Point)
epc8001ExtSensorName
.100.1.6.1.1.32.x
OCTETS
RW
A textual string containing name of a external Sensor
Содержание Expert Power Control 8001
Страница 1: ... 2022 GUDE Systems GmbH Manual Ver 1 0 1 from Firmware Ver 1 0 Manual Expert Power Control 8001 ...
Страница 2: ...2 Expert Power Control 8001 2022 GUDESystems GmbH ...
Страница 5: ...Device Description ...
Страница 12: ...Operating ...
Страница 23: ...Configuration ...
Страница 51: ...Specifications ...
Страница 91: ...Support ...
Страница 97: ...97 Expert Power Control 8001 2022 GUDESystems GmbH Expert Pow er Control 8001 2022 GUDE Systems GmbH 3 16 2022 ...