GÜDE 85023 Скачать руководство пользователя страница 12

Installation / first use

This appliance is equipped with a 

40 cm gas hose for

connection

 – to ensure correct functioning, 

a pressure

regulator for 50 mbar on the cylinder 

is absolutely

necessary. We recommend the following pressure
regulators according to the purpose of use:

  Leisure time use – e.g. terrace, outdoors space, tent

vestibule, party tents etc., with adequate air in-take
and exhaust, 

pressure regulator

 

50 mbar

  For home use (any in-doors spaces) in compliance

with TRF1996-5.2.7.2 (amendment valid from the 1

st

 of

June 2000) and for all industrial liquid-gas devices
(indoors and outdoors) in compliance with UW BGV
D34 section 11 par. 3 and 4: 

two-stage safety

pressure regulator ,,t" 50 mbar with pressure
gauge  (not included).

Installation of the back cover - illustration 1:

To install the back cover, follow steps A, B and C:

Turn the gas cylinder around until the opening points
outwards, to provide good access to the gas valve.

Make sure the base of the gas cylinder is positioned
between the wheels support holder cubes.

Install the back cover by placing the four hooks into
the openings in the protective cover.

Installation of the bottom - illustration 2:

(1) 

Take out the 

plastic button (E). Both cocks (C) of

the bottom part (B) 

must be fully inserted into the

back openings of the 

bottom (A) 

in the

 

relevant

hollows

 

(D)

.

Place 

the plastic button (E)

 you took out earlier into both

bottom openings 

(A) 

and 

(B)

.

Safety instructions – operation

General instructions for liquid gas cylinders handling:

Characteristics of liquid gas:

The liquid gas (propane, butane and their mixes) is a
highly flammable, colourless gas with strong smell. It is
heavier than air and it is flammable when mixed with even
a small amount of air.

 

Warning! Gas leaking without control can burst

into flame or explode.

The liquid gas in the cylinder is pressurized. Protect it from
temperatures over 40°C! Higher temperature, especially
due to fire, causes risk of uncontrolled gas leak and even
an explosion of the cylinder.

Malfunction procedure:

In case of malfunction and leaks (e.g. smell of gas, sounds
produced by leaking) follow these rules and guidelines:

 

Turn the cylinder valve off immediately (clockwise).

 

Do not smoke and no not use open fire.

 

Do not turn any electric switch on or off.

 

Do not make phone calls.

 

Open doors and windows, ensure ventilation.

 

If possible, carry the leaking cylinder outside of the
building.

 

Leave the building and advise technical help of the
situation.

Safety prevention means:

 

Touch protection at the device should prevent fire and
burns; no part of the protection can be taken off
permanently.

 

Full protection is not provided for children and ill

persons!

 

The heating device is equipped with a low-oxygen
safety device. If a higher concentration of carbon

dioxide (CO2) is detected in the room, the safety
device will automatically shut the appliance off. The
appliance cannot be turned back on until the room is
ventilated properly.

 

After use of the heating device, the cylinder valve
must be turned off!

Operation

After having read 

the general safety instructions and

the device-specific safety instructions and having
understood them,

 you can start operating the device.

Follow these instructions:

Installation of the gas cylinder:

 

The device uses a mixture of propane and butane
under pressure of 50 mbar.

 

To operate the device, a gas cylinder with liquid gas
of max. 11 kg of filling is necessary, the hose is pre-
installed.

 

Gas regulator must be selected and/or purchased first
of all, depending on the purpose of use.

 

Installation or change of cylinder with liquid gas must
be performed in non-flammable atmosphere.

 

When the device is not in use and during change
of the cylinder, the device valve must be turned
off.

 

The tightness must be checked at first use and during
each change of the cylinder, using a bubble-
producing means (e.g. soap water).

 

Tightness is proven when no bubbles appear.

 

It is strictly forbidden to check tightness by open

flame!

 

The cylinder must be placed in such a position so that
it is not in contact with the sheet metal of the burner
and the gas supply attached to it. The hose must not
touch (be in contact with) the hot back side of the
burner.

 

The device is supplied with a 40 cm long hose. The
hose must not be shortened or exchanged for a
longer one.

 

Inspect the condition of the hose regularly, at least
during each change of the cylinder.

 

In case of damage to the hose, it must be replaced
with a hose of the same construction, tested
according to DIN DVGVV.

 

Connection of the hose to the regulator must be done
with minimum of V4" left thread. The screw spanner
SW 17 is required for installation.

 

Twisting or distortion of the gas hose during the
installation of the hose and pressure regulator to the
liquid gas cylinder is not permissible.

 

Warning! The hose must not touch (be in contact

with) the hot back side of the burner!

 

Operation with pressure regulators other than those
prescribed above is prohibited.

 

Make sure the hose and regulator are changed after
5 years at the latest.

Connection of the liquid gas cylinder:

 

Take the protective cover of the valve off.

 

Take the covering nut from the attachment socket off
by turning (right).

 

Check the rubber seal in the cylinder valve (regulator
connection).

 

The regulator and the hose must be screwed on
tightly (left thread). No not use any tool or instrument.
Do not turn the regulator but the sleeve nut.

 

Check the tightness of the connection.

Change of the liquid gas cylinder:

 

Close the cylinder valve

 

Unscrew the regulator.

12

Содержание 85023

Страница 1: ...rkichstrasse 6 D 74549 Wolpertshausen Deutschland Deutsch 2 Originalbetriebsanleitung KATALYT FEN English 8 Translation of original operating instructions CATALYTIC STOVES e tina 14 P eklad origin ln...

Страница 2: ...1 2 3 2...

Страница 3: ...ung lesen Vor ffnen Netzstecker ziehen Umweltschutz Abfall nicht in die Umwelt sondern fachgerecht entsorgen Verpackungsmaterial aus Pappe kann an den daf r vorgesehen Recycling Stellen abgegeben werd...

Страница 4: ...ollten vom Arbeitsplatz fern gehalten werden Achten Sie auf das Stromkabel Ziehen Sie nicht am Kabel Fassen Sie zum Abziehen nur den Stecker Halten Sie das Kabel fern von W rmequellen l und scharfen K...

Страница 5: ...alifizierte rztliche Hilfe an Bewahren Sie den Verletzten vor weiteren Sch digungen und stellen Sie diesen ruhig F r einen eventuell eintretenden Unfall sollte immer ein Verbandskasten nach DIN 13164...

Страница 6: ...sinn Rauchen Sie nicht und vervvenden Sie kein offenes Feuer Bedienen Sie keine Elektroschalter Nicht telefonieren Offnen Sie T ren und Fenster sorgen Sie f r L ftung Wenn m glich bringen Sie die undi...

Страница 7: ...und haben nun die h chste Heizstufe Wenn die Z ndflamme jedoch ausgeht wiederholen Sie den Vorgang Die Heizleistung k nnen Sie verringern indem Sie den Einstellknopf leicht eindr cken und auf das mit...

Страница 8: ...Gas cylinder base Wheels support holder cubes 1 2 3 8...

Страница 9: ...nstructions Read the Operating Instructions before use Pull the plug off the socket before opening covers Environment protection Do not throw into general garbage bin dispose of through specialized co...

Страница 10: ...rs especially children and ill persons should not linger around the workplace Pay attention to the electric cable Never pull at the cable To unplug the device pull the cable by the plug The cable must...

Страница 11: ...help communicate the following facts to the operator 1 Place of injury 2 Type of incident or accident 3 Number of persons injured 4 Type of injury The designed purpose of use of the device The device...

Страница 12: ...he heating device is equipped with a low oxygen safety device If a higher concentration of carbon dioxide CO2 is detected in the room the safety device will automatically shut the appliance off The ap...

Страница 13: ...The catalytic gas plate is slightly hot only in the area of the starting flame but the full heating output is spread over the whole catalytic plate The slight smoke fresh paint will dissipate after he...

Страница 14: ...Na b zi plynov lahve P idr ovac kostky kole ek 1 2 3 14...

Страница 15: ...ivotn ho prost ed Odpad nezahazovat n br odborn zlikvidovat Obalov materi l z lepenky je mo n odevzdat k recyklaci na p slu n m m st kodliv nebo k likvidaci ur en elektrick nebo elektronick p stroje m...

Страница 16: ...ut Bu te v dy pozorn Dbejte na to co d l te Pou vejte zdrav lidsk rozum Elektrick n stroje nepou vejte pokud jste unaven Dejte pozor na po kozen d ly N stroj p ed pou it m prohl dn te Jsou n kter d ly...

Страница 17: ...0 V 50 Hz Maxim ln v kon plyn 3100 W Maxim ln v kon elektro 1000 W 2000 W Spot eba min 226 g h Jmenovit tlak p ipojen 50 mbar Hmotnost 13 kg Artikl 85023 Katalytick kamna Nomin ln v kon 3100 W Spot eb...

Страница 18: ...na ventilu l hve vypnut P i prvn m uveden do provozu a po ka d v m n l hve mus b t zkontrolov na t snost pomoc prost edku tvo c ho p nu nap m dlov vody T snost je zaru ena kdy nedoch z k niku bublin...

Страница 19: ...1000 W dodate n k v konu norm ln ho spalov n plynu za zen m S ov kabel sto en uvnit za zen 1 napojit do z suvky 230V 50Hz Stisknout sp na topn ho ventil toru kter m 4 polohy 2 ventil tor vypnut jen ve...

Отзывы: