GuardTronic GTWAE7-4D Скачать руководство пользователя страница 2

 

Long-distance remote control 

The alarm can be controlled by keypad and remote controller, by telephone line, it can be long-distance controlled, and 
fulfill arm/disarm/monitor hearing function. 
 

 

Intelligent study. 

Wireless detector study is very simple. The study time need no 1sec. 

 
Connection line   

1. connect phone line: connect controller to workable phone path. NOTE: if not connect phone line, controller will give"path 
trouble"prompt.   
2. Connect power adapter: the adapter requires: input 230VAC, output 12VDC, and current 1000mA. During AC power is on, 
standby battery will be charged automatically. When AC power cut off, the product works by standby battery entirely.   
3. conncetion terminal: 

·

power output terminal[terminal 1

+

)、

2

-

output DC12V power, can power supply for LX-AL6. 

·

siren terminal[terminal 3

-

4

+

siren power:DC12V, current:800mA 

·

detector signal terminal[terminal5

6

7

8

GND(2,3)]

 

controller has 

wired arm zone:

[5-

GND

is 01 zone

[6-

GND

is02 zone

[7-

GND

is 03 zone

[8-

GND

is 04 zone. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Function setting 

·

·

·

·

enter programming 

              The  controller’s  system  password  is  [000000],  all  settings  and 

modifying of the controller must be done via system password. The user 
password is [1234]. 

              Attention: the system password is the highest grade; only via it you 

can modify the user password and all specification of the controller. So 
when  you  modify  the  system  password,  you  must  remember  the  new 
password firmly.     

              After connection line right, switch on power, the POWER led light; 

when the controller is in arm state or guard st, the ARM led light. LCD 
display the controller’s state(“Arm St” or “Guard St” or “Disarm St”)

that indicate it is normal. 

              Attention: when LCD display “Arm St” or “Guard St”, if you need to program, you need to input user password to disarm 

controller, when LCD display “Disarm St”, you can start to program. 

 
 
 
 
            When controller is in disarm state (disarm st), press the SET key on keypad, LCD display <input level> and remind you input 

the system password, press # key to enter the main menu. 

 
 
 

 

 

POWER

ARM

A

B

C

0

#

8

TUV

9

WXYZ

4

GHI

5

JKL

6

MNO

3

DEF

2

ABC

1

AWAY

HOME

SET

MEDICAL FIRE

HELP

7

PQRS

Disarm St

 

Input level 

****** 

1.Sys   2.Zone 

3.Setup  4.Study 

siren

controller inner PCB

phone line

1

3

O

N

P

U

L

S

E

L

E

D

O

F

F

-4

-6

0

4

2

-2

TAMPER

+

_

RELAY

LX-AL6 inner PCB

_

12VDC+

power output

power adapter

TAMPER RELAY

Содержание GTWAE7-4D

Страница 1: ...LX AL7 double detectors PIR LX AL11 wired or wireless PIR LX AL9 Function 4 8 arm zone LX HS06 has 4 wired arm zones and 8 wireless arm zones English display Its operation and setting all be displayed by English and operation is more convenient and shortcut Function mightiness Possessing multiple programmable function setting operation and setting is simple standby power for 24 hours One key opera...

Страница 2: ... s system password is 000000 all settings and modifying of the controller must be done via system password The user password is 1234 Attention the system password is the highest grade only via it you can modify the user password and all specification of the controller So when you modify the system password you must remember the new password firmly After connection line right switch on power the PO...

Страница 3: ...save only the last password please remember new password firmly 2 modify user password user level enter menu 1 level 2 user level LCD display input user level input 4 bit password and press key to confirm The system save only the last password please remember new password firmly code setting center network code 2 code no the setting temporarily report setting3 report Enter menu 3 report LCD displa...

Страница 4: ... alarm help alarm separately When select 4 bypass the arm zone do not work setting 3 setup siren alarm time setting1 alert enter menu 1 alert LCD display After inputting press key to confirm is siren s alarm delay can set to 000 999sec factory set to 300sec guard setting2 home enter menu 2 home LCD display After inputting press key to confirm is the arm zone NO guarded When host is at home after h...

Страница 5: ...disarm st Home Arm press the Home arm or press HOME key on keypad controller give system arm prompt sound and LCD displays guard st help alarm Remote control press the help alarm key on remote controller controller dial and then the siren alarm controller give help alarm alarm info Keypad operation press and hold MEDICAL FIRE HELP key for 3sec DI DIDI prompt sound will be heard controller dial and...

Страница 6: ...LED When battery energy is below 7V the low battery LED will flash once a second and remind you replace battery Avoid installing the unit on metal base Avoid installing the unit where sun shine or temperature change obviously for example air conditioning heater etc Door magnetism LX DM1 Install magnetism and emitter on upright position of door lock the distance between them is 3mm 5mm and triangle...

Отзывы: