11
H. Manufacturer Default Settings
Listed below are the factory settings for your driveway alarm system.
NOTE: Your system has been preset by the manufacturer to the most com-
monly used settings. It is recommended that users test the unit(s) under the
default settings before making adjustments. If you have questions about
these settings, please contact Customer Service.
Receiver
Sensor
Pause Time
30 minutes
Interval “Sleep”
Timer
7 seconds
Pause Mode
EU
OFF
Delay Time
1 second
Filter
3-6.5 (0.9~2m )/sec
12V Ou tputs
all OF F
Distance
Sensitivity
39 (12m)
NO /NC Control all OF F
Why Change Settings?
Though your Guardline Driveway Alarm System is factory set to suit the most com-
mon user, sometimes your needs may require more complicated settings. For in-
stance, you may need to turn On the night mode
to enable motion detection
if your sensing area is dark or dimly lit, or if your sensing area is only a sidewalk-width
away and not across the road, you may want to change Distance Sensitivity to just 13
feet (4m).
UserManual_v7_11.28.15_actual size_FINAL.indd 1
Night Mode
12
A. Pause Time Setting:
B. Pause Mode:
In EU Mode, the receiver will automatically turn on after the
pause has timed out. In US Mode, the receiver will BEEP when the pause time is
over, but will NOT automatically turn on.
Halts receiver operation for an extended time of either
30 or 60 minutes. Press and hold the “Pause/Reset” button on the side of the
receiver for 3 seconds to enter Pause mode.
E. 12V Output Control:
Assigns a zone to the 12V Output terminal (“D”) for ex -
ternally wired devices.
F. NO/NC Control:
Selects which zone will connect with the NO/NC terminals.
D. Output Terminal:
External devices, such as gate openers, door releases, or external speakers, can be
wired to the receiver using the 12V out relay.
• 12V Out:
This terminal outputs 12V/300mA when the selected zone has been
triggered in cooperation with “E” (12V Output Control).
This function is dis
abled when running on batteries.
Select which zone relays to this output by
sliding ONE of the dip switches for zones 1, 2, 3, or 4 to the “On” position.
• NO (Normal Open):
Outputs to a closed circuit when the selected zone has
been triggered.
• COM:
Neutral/Grounding terminal.
• NC (Normal Closed):
Outputs to an open circuit when the selected zone has
been triggered.
• The NO and NC outputs cooperate with “F” (NO/NC Control). You can select
which zone relays to these outputs by sliding ONE of the dip switches 1, 2, 3,
or 4 to the “On” position.
C. Delay Time Setting:
This is primarily used in setups with multiple sensors per
zone. This setting adjusts how many seconds must pass before the receiver is able
to chime again. Ex. If you have multiple sensors installed along your driveway,
you may want to change this setting to 60 seconds so you are only notified once
when the first sensor goes off and not by any subsequent alerts for up to 60
seconds.