Installation and Use

1. Inspect Guardian Non-Shock Absorbing Lanyards and all PFAS equipment to be used in combination with
Non-Shock Absorbing Lanyards.

2. Ensure that all connectors and all other components of the PFAS are compatible with Guardian Non-Shock
Absorbing Lanyards, and are selected by a Competent Person. The selected safety harness MUST be of proper
size, and MUST be fitted snugly, but still allow for a full range of movement.

3. Make considerations for eliminating or minimizing swing fall hazards.

4. Ensure structure to which the anchorage connector is attached is capable of withstanding a MINIMUM load
relative to the application with which the Non-Shock Absorbing Lanyard is to be used.

5. Attach lanyard snap hook, carabiner, or web loop (as applicable) to compatible harness D-ring. If using in
combination with shock absorber extension, ALWAYS locate the shock absorber end at the applicable harness
D-ring. The shock absorber MUST NEVER be located at the anchorage connector.

6. Attach remaining snap hook or carabiner end of lanyard to compatible anchorage connector. Rebar Hooks
MUST ONLY be connected to structural rebar. Ensure that all connectors are self-closing and self-locking, and
that there is no risk of roll-out.

7. NEVER work with employed harness D-ring positioned above the anchorage connector, unless permitted by
specific application or combination of equipment. A Competent Person must make a determination regarding
the acceptability of working above an anchorage connector.

8. Only use Guardian Lanyards in the fall protection application(s) for which they are designed. Refer to
product labeling, or contact Guardian Fall Protection if unsure of proper application(s).

NEVER use Non-Shock Lanyards for material handling.

!

WARNING

Содержание Non-Shock Lanyard

Страница 1: ... these instructions Read and understand these instructions before using equipment Introduction 1 Applicable Safety Standards 1 Worker Classifications 1 Safety Information 6 Product Specific Applications 1 2 Limitations 2 3 Components and Specifications 3 Maintenance Cleaning and Storage 5 Inspection 5 Installation and Use 4 Inspection Log 5 Labels 7 ...

Страница 2: ...is considered proficient in planning and reviewing the conformity of fall protection and rescue systems Competent Person A highly trained and experienced person who is ASSIGNED BY THE EMPLOYER to be responsible for all elements of a fall safety program including but not limited to its regulation management and application A person who is proficient in identifying existing and predictable fall haza...

Страница 3: ...is possible Rescue Confined Space Non Shock Lanyard may be used in Rescue Confined Space applications Rescue systems function to safely recover a worker from a confined location or after exposed to a fall There are various configurations of Rescue systems depending on the type of rescue Structure must withstand loads applied in the directions permitted by the system of at least 3 000 lbs No free f...

Страница 4: ...nyard NO Two or more snap hooks or carabiners connected to each other NO Two connectors to same D ring NO Connector directly to horizontal lifeline NO Connector directly to webbing NO Incompatible or irregular application which may increase risk of roll out NO Part Size Description 01280 01250 01260 01265 4 6 3 4 2 01255 6 Adjustable Non Shock Absorbing Lanyard Non Shock Absorbing Lanyard Single L...

Страница 5: ...b loop as applicable to compatible harness D ring If using in combination with shock absorber extension ALWAYS locate the shock absorber end at the applicable harness D ring The shock absorber MUST NEVER be located at the anchorage connector 6 Attach remaining snap hook or carabiner end of lanyard to compatible anchorage connector Rebar Hooks MUST ONLY be connected to structural rebar Ensure that ...

Страница 6: ...ble work area is free of all damage including but not limited to debris rot rust decay cracking and hazardous materials Ensure that selected work area will support the application specific minimum loads set forth in this instruction manual Work area MUST be stable At least every 6 months a Competent Person other than the user must inspect Non Shock Lanyard Competent Person inspections MUST be reco...

Страница 7: ...est falls within 24 Class B SRLs must arrest falls within 54 Harnesses and connectors selected must be compliant with manufacturer s instructions and must be of compatible size and configuration Snap hooks carabiners and other connectors must be selected and applied in a compatible fashion All risk of disengagement must be eliminated All snap hooks and carabiners must be self locking and self clos...

Страница 8: ... fall arrest system Remove this lanyard from service if a fall has been incurred WARNING Follow manufacturer s instructions provided with this lanyard at time of shipment from manufacturer Fully read and understand these instructions before using Improper use of this product could result in serious injury or death Avoid contact with sharp edges and abrasive surfaces that can cut or damage the webb...

Отзывы: