Guardian Telecom Inc.
Installation and Operation
Model HR60
Page 5
Installing the HR60
•
If Pulse dialing is required refer to the Maintenance section
•
Follow all appropriate electrical codes and use only approved electrical
fittings for the installation.
See: Figure 3 - Internal
•
Choose a wall location that is free of obstructions and permits space for
wiring or ½” NPT conduit runs if required.
See: Figure 1 - Mounting
•
Ensure mounting can support 4lbs (1.8kg) and any additional foreseeable
load.
•
Ensure that none of the electrical connection circuits are live.
•
Use the template provided to locate and drill holes for #10 or M5 mounting
screws.
•
Remove the eight #10 Philips drive faceplate screws, remove the faceplate
and unplug the harness.
Note: Be careful when
removing the faceplate,
the circuit board is on the
faceplate.
•
Secure the unit to the wall.
Tip: Use #10 or M5
screws to secure the unit
to the wall.
•
For Model P6260 (with a 7/8” entry hole): install a suitable grommet or hub
and bring cable into the enclosure through the entrance. Attach individual
wires from the exchange (Tip/Ring/Ground) to the terminal strip (Tip & Ring
are not polarity sensitive). If a conduit hub is used, ensure it is grounded to
the ground stud.
See: Figure 3 - Internal
Layout
•
For Model P6264 (with a ½” conduit hub): bring cable into the enclosure
through the conduit entrance and attach individual wires from the exchange
(Tip/Ring/Ground) to the terminal strip (Tip & Ring are not polarity
sensitive.). Ensure that the conduit hub is grounded to the ground stud.
•
Reconnect the harness, ensure all connections are tight, then replace the
faceplate and secure with eight #10 Philips drive screws.
•
Apply power to the system.
•
Test the unit by calling to and from another unit on the exchange.