2.2 Installing the Heating Unit
Place the heater bracket with attached heating unit over
the base and tighten the two studs into place. Route the
cable through the two cable mounts located on the
power supply bracket and base, to the terminal block.
2.2.1 Options Power Supply Connection
Connect the green and yellow ground wire from the
power cord and the six-inch green and yellow ground
wire jumper to the ground stud located next to the
printer power switch. Be sure the wires are securely
positioned between the two stud nuts. Attach the other
end of the six-inch green and yellow ground jumper
wire to the upper right connection of the terminal
block. Route the blue and brown wires from the options
power cord through the cable mount to the lower right
and middle right connections on the terminal block as
shown in the diagram below. Apply adhesive ground
sticker next to ground stud on base.
2.2.2 Heater Cord Connection
Attach the heater cord to the terminal block as shown
in the diagram below.
Heater Cord
If you are installing only the heater option, slide the
protective warning shield over the terminal block
standoffs and secure with two nuts.
1.5 Close Cover
Close and latch the cover. Tighten the butterfly
lockdown latches. Open the label access door to begin
printing labels.
Note:
Be sure to close the label access
door before cleaning the enclosure.
2.0 Enclosure Options
Optional features of the Guardian
G-2 CS Printer
enclosure include:
•
Heating unit
•
Axial ventilating fan
2.1 Attaching the Terminal Block
Before installing the axial venting fan or heating unit,
you must attach the terminal block to the side of the
power supply bracket. To do this, align the insulator
plate and block with the appropriate holes and tighten
into place with two standoffs and screws. Adhere a
cable mount on each side of the terminal block. (See
diagram on page 4.)
Green
Black
White
Green and Yellow
Brown
Blue
Options
Power Cord