Product Specific Applications

Personal Fall Arrest:

 Concrete Swivel Anchor may be used to support a MAXIMUM 1 PFAS for use

in Fall Arrest applications. Structure must withstand loads applied in the directions permitted by
the system of at least 5,000 lbs. Maximum free fall is 6‘, or up to 12’ if used in combination with
equipment explicitly certified for such use. Applicable D-ring: Dorsal.

Restraint:

 Concrete Swivel Anchor may be used in Restraint applications. Restraint systems

prevent workers from reaching the leading edge of a fall hazard. Always account for fully
deployed length of lanyard/SRL. Structure must withstand loads applied in the directions
permitted by the system of at least 1,000 lbs. No free fall is permitted. Restraint systems may
only be used on surfaces with slopes up to 4/12 (vertical/horizontal). Applicable D-rings: Dorsal,
Chest, Side, Shoulder.

!

WARNING

Use of equipment in unintended applications may result in serious

injury or death. Maximum 1 attachment per connection point.

For all applications: worker weight capacity range

(including all clothing, tools, and equipment) is 130-420 lbs.

Limitations

Fall Clearance:

 There must be

sufficient clearance below the
anchorage connector to arrest a
fall before the user strikes the
ground or an obstruction. When
calculating fall clearance,
account for a MINIMUM 2’ safety
factor, deceleration distance, user
height, length of lanyard/SRL,
and all other applicable factors.

Diagram shown is an example
fall clearance calculation ONLY.

Swing Falls:

 Prior to installation

or use, make considerations for
eliminating or minimizing all
swing fall hazards. Swing falls
occur when the anchor is not
directly above the location where
a fall occurs. Always work as close
to in line with the anchor point
as possible. Swing falls
significantly increase the
likelihood of serious injury or
death in the event of a fall.

Rescue/Confined Space:

 Concrete Swivel Anchor may be used in Rescue/Confined Space

applications. Rescue systems function to safely recover a worker from a confined location or after
exposed to a fall. There are various configurations of Rescue systems depending on the type of
rescue. Structure must withstand loads applied in the directions permitted by the system of at
least 3,000 lbs. No free fall is permitted. Applicable D-rings: Dorsal, Chest, Shoulder.

Work Positioning:

 Concrete Swivel Anchor may be used in Work Positioning applications. Work

Positioning systems allow a worker to be supported while in suspension and work freely with
both hands. Structure must withstand loads applied in the directions permitted by the system of
at least 3,000 lbs. Maximum allowable free fall is 2’. Applicable D-rings: Side.

Fall clearance calculation shown based on standing worker

falling directly in-line with anchor point. Always consider potential

swing fall and other hazards when calculating fall clearance.

*Eliminate Swing Fall whenever

possible! If Swing Fall exists,

always account for additional

fall clearance.

1.5’

2’

12’

5’

Anchor Point

at Foot Level

12’ Free Fall 

Lanyard

Anchor Point

Level w/Dorsal D-ring

6’ Free Fall 

Lanyard

2’

Содержание 00240

Страница 1: ...d and understand these instructions before using equipment Introduction 1 Applicable Safety Standards 1 Worker Classifications 1 Safety Information 6 7 Product Specific Applications 1 2 Limitations 2...

Страница 2: ...clude state specific regulations Consult regulatory agencies for more information on personal fall arrest systems and associated components Worker Classifications CAUTION Understand the following defi...

Страница 3: ...of lanyard SRL and all other applicable factors Diagram shown is an example fall clearance calculation ONLY Swing Falls Prior to installation or use make considerations for eliminating or minimizing...

Страница 4: ...rrect Anchorage Positioning This chart details allowable working zones required to reduce risk of swing falls and improper side loading ALWAYS adhere to information specified by chart Anchor Distance...

Страница 5: ...ls 5 Concrete Swivel Anchor is rated for loading in any direction provided it is installed as prescribed Suitable for use in HLL applications Substrate requirements DO NOT install onto wood steel holl...

Страница 6: ...ere it will not be affected by heat light excessive moisture chemicals or other degrading elements 4 3 8 1 2 3 4 5 6 Installation 1 Use rotary hammer and drill bit to drill hole into concrete Bit size...

Страница 7: ...ment inspection grid label The Competent Person must sign their initials in the box corresponding to the month and year the inspection took place During inspection consider all applications and hazard...

Страница 8: ...t Person Training must include the ability to recognize fall hazards minimize the likelihood of fall hazards and the correct use of personal fall arrest systems NEVER use fall protection equipment of...

Отзывы: