9.  Installation 

Follow all appropriate electrical codes and use only approved electrical fittings for the 
installation. 

 

Determine if power to operate the telephone will be provided via the Ethernet or if 
external power will be required. If external power is required install Guardian’s Auxiliary 
Power Supply or equivalent. 

See: 

Figure 5 - Terminal Block 

Connections

 

To maintain Ingress Protection / NEMA ratings use appropriately rated hardware and 
waterproofing techniques. 

 

Choose a wall location that is free of obstructions and permits space for conduit runs. 

See: Figure 3 - Overall Dimensions 

Ensure mounting can support 7 lbs (3.2kg) and any additional foreseeable load. 

 

To Avoid The Danger Of An Accidental Shock or Circuit Damage 

 

o

 

If using aux power supply, ensure it is unplugged during installation. 

 

Separate the faceplate from the housing. 

Use the template provided or the enclosure itself to locate and drill holes for mounting 

screws. 

Note: Be careful when removing the 
faceplate. The circuit board is on the 
faceplate.

 

Secure the unit to the wall. 

Bring the Network cable into the enclosure through the conduit entrance and plug into 
the RJ-45 connector on the PCBA. 

Tip: Use ¼” or M8 screws to 
secure the unit to the wall. 

If using an alternate power supply connect the supply to the terminal block J9. Before 
doing so determine if power is supplied over the Ethernet cable. 

See: Figure 5 - Terminal Block 
Connections 

Connect the on-board relay if utilized. 

Reconnect the faceplate harness. 
Ensure all connections are secure. 

See: Section 13.2 Connecting a 
Device to the Auxiliary Relay  

Determine that the telephone is properly connected by pressing the RESET switch for 
less than five seconds to announce the IP address. LEDs on the RJ45 connector 
indicate network connection and activity. 

See: Section 13.5 RESET Switch 
and Figure 8 - Network Activity 

Replace the faceplate. 

 

Set up and configure if changes are required to the default settings.

 

Test the unit by calling to and from another telephone, preferably a VoIP device. 

See: Manual P007402 – Setup 
and Configuration. 

 
 

10.  Operation 

WRT-VoIP telephones may be set up for either keypad dialing or auto-dialing. 

If the telephone is configured for keypad dialing operation is identical to most other 
single line telephones. 

Note: The details are explained in 
the Setup and Configuration 
Manual P007402. 

If the telephone is configured for auto dialing lift the handset and press the number 
assigned to the extension to be dialed. 

 

WRR-VoIP telephones will dial the programmed number when the handset is lifted. 

 

Adjust the receiver volume with the switch in the handset. 

 

 
 

Содержание P6300

Страница 1: ...er Resistant VoIP Telephones WRR WRT VoIP Series Installation Operation WRT 10 VoIP WRR 41 VoIP P007332 Rev D 150916 9 16 2015 1 32 PM Ph 403 258 3100 email info guardiantelecom com www guardianteleco...

Страница 2: ...any use of this manual or such products software firmware and or hardware Guardian Telecom Inc reserves the right to make changes without notice to this manual and to any such product software firmwa...

Страница 3: ...2 Keep these instructions 3 Heed all warnings 4 Follow all instructions 5 Install in accordance with the manufacturer s instructions 6 Do not install near any heat sources such as radiators heat regis...

Страница 4: ...Data Rate 14 13 4 1 Verify Network Activity 14 13 5 RESET Switch 15 14 Announcing the IP Address 15 15 Restore the Factory Default Settings 15 16 Adjust the Volume 15 17 Product Specifications 16 18...

Страница 5: ...gdown telephone with 4 curly cord P6305 WRR 41 VoIP Weatherproof ringdown telephone with armored handset cord 3 Options Stainless Steel Mounting Plate MP Standard on WRR 41 VoIP WRT 40 VoIP 20 Heavy D...

Страница 6: ...program settings through a web browser to configure telephones on their network WRR 11 VoIP WRT 10 VoIP and WRT 30 VoIP are standard models with a curly cord WRR 41 VoIP and WRT 40 VoIP are vandal re...

Страница 7: ...Compatible Receiver Volume Adjustment Compatible with inductively coupled hearing aid devices Adaptive full duplex operation Compatible with most SIP based IP PBX servers that comply with SIP RFC 326...

Страница 8: ...Guardian Telecom Inc Installation and Operation WRR WRT VoIP Series Telephones Figure 2 WRT VoIP Features WRR VoIP Similar Figure 3 Overall Dimensions Page 8...

Страница 9: ...Guardian Telecom Inc Installation and Operation WRR WRT VoIP Series Telephones J1 STANDARD 8 PIN RJ45 10 100Base T And power input via Power over Ethernet Figure 4 Wiring Page 9...

Страница 10: ...on the PCBA Tip Use or M8 screws to secure the unit to the wall If using an alternate power supply connect the supply to the terminal block J9 Before doing so determine if power is supplied over the E...

Страница 11: ...sing TFTP Client Facilitates hosting for the Autoprovisioning configuration file RTP Facilitates autoprovisioning configuration values on boot Audio Encodings PCMU G 711 mu law PCMA G 711 A law Packet...

Страница 12: ...oltages See Figure 6 Auxiliary Relay Wiring Diagram Warning The relay circuitry contains a non replaceable 250VAC 1A fuse If the fuse blows the board must be returned to Guardian or an approved servic...

Страница 13: ...ns and functions Figure 7 Connector Locations Connector Function J1 PoE Network Connection RJ 45 J2 Hands free Microphone Interface LED Interface J3 Not used J4 JTAG Interface J5 Handset Reed Switch I...

Страница 14: ...re green Link light above the Ethernet port indicates that the network connection has been established see Figure 8 The Link light changes color to confirm the auto negotiated baud rate This light is...

Страница 15: ...ned address or default to 10 10 10 10 if a DHCP server is not present Note Pressing and holding the RESET switch for longer than five seconds will restore the telephone to the factory default settings...

Страница 16: ...000 000 OPERATIONS BODY CONSTRUCTION GE VALOX 357 ENGINEERING POLYMER FACEPLATE STEEL CORROSION PROTECTED POWDER COATED DIMENSIONS H X W X D 12 x 9 6 x 3 9 INCHES 305 x 245 x 99 mm NET WEIGHT INCLUDI...

Страница 17: ...of the set Handset Replacement Refer to the instruction sheet included with the replacement handset Disconnect the handset wiring from the PCBA If the phone is equipped with an armored cord handset r...

Страница 18: ...phone P005778 Faceplate WRR VoIP Ringdown P005784 Access Plate P005837 Reed Switch P007228 Handset 4 Curly Cord C W VC Tx Rx Cn P007230 Handset 22 Armored Cord VC Tx Rx Cn P007319 Ringer Floyd Bell Vo...

Страница 19: ...ray the cleaner on a soft cloth then wipe the surface Pre treated cloths like those used for eyeglasses or cameras may be used to clean the Telephone Premoistened towelettes may also be used however a...

Страница 20: ...r the purposes of installing the product making adjustments and replacing components following the instructions in the product manual High voltages may be present in this product when wiring is connec...

Страница 21: ...ns and the unit fails to operate the user must contact Guardian Telecom to obtain authorization to return the product This can be done by done by completing a RMA form online at www guardiantelecom co...

Страница 22: ...Guardian Telecom Inc Installation and Operation WRR WRT VoIP Series Telephones Page 22 Notes Model No Part No Serial No Date of Purchase...

Страница 23: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 24: ...ian Telecom Inc Toll free 1 800 363 8010 Phone 403 258 3100 Fax 403 253 4967 www guardiantelecom com E mail sales guardiantelecom com Click to open message box CONNECTED PROTECTED Guardian Telecom Inc...

Отзывы: