Guardian Telecom
Installation and Operation
DTR/DTT-VoIP Series Telephones
Page 9
Figure 4 - Wall Installation of Base
4.
Installation
Enclosure
Follow all appropriate electrical codes and use only approved electrical fittings for the
installation.
To Avoid The Danger Of An Accidental Shock or Circuit Damage
o
If using an auxiliary power supply ensure it is unplugged during installation.
o
If using the onboard relay to control an external relay ensure power is off during installation.
The telephone may be installed on a flat surface or wall mounted.
Using the 3mm Allen Key provided, loosen the four faceplate captive screws to detach the
faceplate from the base.
Desk Top Configuration
If the telephone is to be desk top mounted set the base in the desired location.
Wall Mount Configuration
If the telephone is to be wall mounted choose a location that is free of obstructions and permits
space for wiring. Mount the base with the deepest dimension on the bottom. Mount as
follows:
See: Figure 3 - Overall
Dimensions
o
The telephone weighs 3.95 kilograms (8.68 pounds), ensure that the mounting can
support four times the weight of the unit; that is 15.8 kilograms (34.8 pounds).
Wall anchors are not included; follow the manufacturer's instructions when
installing anchors.
o
Mounting to concrete or cinder block. Lead expansion anchors with M4 (#8)
screws are recommended.
o
Mounting to drywall. Hollow wall anchors (Molly Bolts) with M4 (#8) screws are
recommended.
o
Mounting to other surfaces. It is the responsibility of the installer to ensure that the
base is attached in such a way as to support the weight specified above.
Install the handset retainer clips on the faceplate using the hardware supplied.