Installation:

1. Loosen Clamp Bolts so Friction Fit Bracket will fit over selected 2” x 4” fascia board. Friction
Fit Bracket must be installed from bottom of fascia board. Clamp Bolts must face away from
work area.

2. Place Friction Fit Bracket onto selected fascia board, and ensure that, when closed, Clamp
Plates will lie completely flush against fascia board.

3. Tighten both Clamp Bolts to 30 foot-pounds. Use a correctly calibrated torque wrench to
ensure both Clamp Bolts are torqued properly.

4. Repeat steps 1-3 for all Friction Fit Brackets at all selected installation locations.

5. Install all required guardrail posts into Friction Fit Bracket Guardrail Post Installation Locations.
Guardrail post rungs must face in towards work surface. 

Work Surface

Guardrail rungs
face in towards
work surface.

Clamp Bolts
face away from
work surface.

6. Install all guardrails. Guardrails may be compatible snap-on metal rails, or 2” x 4” or
2“ x 6” construction grade lumber. If using lumber guardrails, guardrails MUST overlap a
minimum of 12” at each end between consecutive guardrail posts.

Clamp Plates flush
against fascia board.

Clamp Bolts
torqued to 30
foot-pounds.

Guardrail post
fully inserted into
Guardrail Post
Installation Location.

Minimum 12”
guardrail overlap
(for lumber guardrails).

Содержание 15026

Страница 1: ...Product Name Friction Fit Bracket Instruction Manual Part 15026 Do not throw away these instructions Read and understand these instructions before using equipment...

Страница 2: ......

Страница 3: ...n Friction Fit Bracket This manual must be read and understood in its entirety and used as part of an employee training program as required by OSHA or any applicable state agency This and any other in...

Страница 4: ...r sufficient professional standing who is considered proficient in planning and reviewing the conformity of fall protection and rescue systems Competent Person A highly trained and experienced person...

Страница 5: ...he maximum allowable free fall distance for lanyards must not exceed 6 No free fall allowed for non LE SRLs Class A SRLs must arrest falls within 24 Class B SRLs must arrest falls within 54 Forces app...

Страница 6: ...ence of cracks sharp edges deformation corrosion excessive heating alteration excessive wear fraying knotting abrasion and absence of parts Equipment that fails inspection in any way must immediately...

Страница 7: ...it Bracket for deficiencies including but not limited to corrosion deformation pits burrs rough surfaces sharp edges cracking rust paint buildup excessive heating alteration and missing or illegible l...

Страница 8: ...ystems are placed around the leading edges of any and all fall hazards to prevent a worker from going over an edge and may be used in substitute of Fall Protection or safety netting systems Installati...

Страница 9: ...r deceleration distance user height length of lanyard SRL and all other applicable factors Diagram shown is an EXAMPLE fall clearance calculation ONLY Swing Falls Prior to installation or use make con...

Страница 10: ...g and withstand minimum loads of 3 600 lbs See the following for examples of compatible incompatible connections Connector closed and locked to D ring OK Two or more snap hooks or carabiners connected...

Страница 11: ...6 10 15 20 25 30 35 40 45 50 55 60 8 9 9 11 7 13 3 14 6 16 17 2 18 3 19 4 19 10 21 4 22 3 53 45 38 33 30 28 26 24 23 21 21 21 For example if the anchorage connector is 6 from the leading edge Y the wo...

Страница 12: ...ction 6305 S 231st St Kent WA 98032 phone 800 466 6385 fax 800 670 7892 www guardianfall com 10 Materials zinc plated steel 5 4 Clamp Bolts Zinc plated steel 1 2 13 x 5 Grade 5 Clamp Plates Clamp Bolt...

Страница 13: ...or compatible snap on metal rails 4 Toprails must be 42 3 above the work surface or if used in stilt work applications 42 plus height of stilts 5 Midrails must be halfway between the top edge of the g...

Страница 14: ...ed properly 4 Repeat steps 1 3 for all Friction Fit Brackets at all selected installation locations 5 Install all required guardrail posts into Friction Fit Bracket Guardrail Post Installation Locatio...

Страница 15: ...m 1 800 466 6385 6305 S 231st St Kent WA 98032 Friction Fit Bracket Part 15026 Prior to use read and understand all manufacturer s instructions provided with equipment at time of shipment from manufac...

Страница 16: ...Use __________________ Product lifetime is indefinite as long as it passes pre use and Competent Person inspections This inspection log must be specific to one Friction Fit Bracket Separate inspectio...