V12AM
Installation
Instructions
Walk Test LED
PCB
Electronics Module
Note: If internal EOL
resistors in use
connect the loop to
terminals 3 and 10
1 2 3 4 5 6 7 8 9 10
NC
ALARM
12 V
Power
NC
AUX
NC
TAMPER
T
E
S
T
C
T
R
L
+
—
Anti-Mask
Light Pipes
Connector Block
Switches
PIR Sensor
(Do not touch)
Declination
Indicator
0m 5m 10m 15m
2.3m
Lens
Module
Main Lens
Main Lens Screws
Tamper Switches
(loosen only, do not remove)
Lens Module
Front Cover
Cover Screw
PCB
A
A
A*
B
B
C
C
A
A
B*
B
Cable Entry
Cable Channel
Base
Knockout Holes:
A - Corner mounted
B - Flush mounted
C - Wall mounted using LPB2 brackets
For the off-the-wall tamper to be operational, screw must
be fitted in either A* or B*
Enabled
Disabled
Enabled
Disabled
10 m
15 m
10 m
15 m
Connected
Off
Connected
Off
Standard
High Security
Standard
High
On
Off
-
-
FACTORY DEFAULTS
1 2 3 4 5 6 7 8 9 10
No.
Function
1
LED Enable
2
Pulse Count
3
PIR Gain 1
4
PIR Gain 2
5
HS EOL1
6
HS EOL2
7
Mode
8
AM Sensitivity
9
AM On/Off
10
Not Used
OFF
ON
Coverage Diagrams
0m 5m 10m 15m
10m
5m
0m
5m
10m