background image

Red

Green

Yellow

SW1

Test

a

b

Fault

Other

Fault

Other

OFF

Low

-

-

-

ON

x

x =don’t care

-

x

High

-

FACTORY DEFAULTS

 No. Function  

 1 

 LED Enable

 2 

Pulse Count

  3  

UW Day disable

  4 

AM / Faults O/P

 5 

AM Sensitivity

 6 

Anti-Stealth

Enabled Disabled

ON OFF

Enabled Disabled

Faults on 

Aux 

 AM on 

Aux

High Sensitivity 

 Standard

Enabled  

Disabled

OFF

 ON

  

 1     2    3     4      5     6

     

Use in EN50131 Compliant Systems

DTSx+15 meets the requirements of TS50131-2-4:2004, Grade 3, Class 
II with SW3 OFF, SW4 and SW5 ON.  

 

Coverage shown applies with unit 

mounted 2.3m high, SW2 OFF, microwave at max and PCB in position B. 
Changing these may affect approval compliance.

Declaration of Conformity :

Hereby Guardall Ltd, declares that DTSx+15/100 is approved for use in 
UK, Italy & Eire and is in compliance with the essential requirements and 
other relevant provisions of EU Directive 1999/5/EC. 

Intended use: 

Within a building as an intruder detection device.

Safety Information: 

The power feed must be fused at 5A or less.

2. Installation Location

The recommended mounting height of the detector is 2.3m.  Ensure 
the detector’s fi eld of view is not obscured. Please refer to Installation 
Guidance Notes available on our website or call the Technical Hotline for 
further information. 

3. Walk testing

Select switch 1 to ON. 
The yellow LED displays PIR activity. The PIR coverage is adjusted by 
loosening the PCB retaining screw, moving the PCB up or down, then 
re-tightening the PCB screw. Position A=Horizontal, B=15m & C=8m.

The green LED displays microwave activity. Range is adjusted via the 
microwave range control (2 in diagram 1). 
The microwave should be set to the minimum necessary to give the required 
coverage. Note that coverage under the unit may also change.

The red LED displays unit alarms.

Walk test the area checking that alarms are indicated at the control 
panel.
Check tamper operation if wired.

4. Operating Feature Selection

SW1: LED enable

 - See LED indications section.

SW2: Pulse Count

In harsh environments select switch 2 ON (pulse count).

SW3: Microwave Day Disable

OFF - the microwave will be permanently active.
ON - microwave is disabled when system Unset.

SW4: Anti-mask / Fault Output

SW4

Faults Signalled On

Mask Signalled On

ON

Aux + LED (if enabled)

Alarm + Aux + LED (if enabled)

OFF

LED

Aux + LED

          
To reset a mask: Remove the mask, wait 30 secs, generate an alarm.
If Switch 3 (UW day disable) is ON the Anti-mask is disabled.

SW5: Anti-Mask Sensitivity

In harsh environments, select switch 5 to OFF.  

SW6: Anti-Stealth

SW6 ON - Enhances detection for high security applications.
Please refer to Installation Guidance Notes available on website or call the 
Technical Hotline for further information. 

5. Remote Self Test (RST)

With switch 4 ON, an 

RST

 is generated when the TEST Input is taken high 

to low. The alarm output will signal a successful 

RST

. A failure will generate 

a fault condition. This is only reset by a successful 

RST

.

6. Alarm Memory

* System Set  
  Should an alarm occur the alarm will be memorised.

* System Unset and SW1 OFF
  TEST Input Low : the red LED will remain ON (if an alarm is 
 memorised). 
  TEST Input High: the LEDs display normally without losing alarm 
 memory. 

Memory reset occurs the next time the system is set.

7. LED Mode Setting

System Set:

 No LED indications

System Unset:

With SW4 OFF, the following table applies.
With SW4 ON, the following table applies except No 

Faults

 are dis-

played unless SW1 is ON or Test is High.

8. LED Indications

Red LED Indications:
a)

 Latched Alarm  

ON constant.

    Anti-Mask 

Fault

:  : 

With latched alarm: Flicker...ON..Flicker..ON.. 

  

  

  etc.

      

 

No latched alarm: Flicker..OFF..Flicker..OFF.. 

  

  

  etc. 

 

  Low Voltage  

One Flash every second.

b)

 Low Voltage  

:   One Flash every second.

  Unit Alarm 

:   ON for 3 secs.

 Anti-Mask 

Fault

 : 

  Flicker..OFF...Flicker..OFF..etc.

Green LED Indications:

Microwave Alarm 

ON for 3 secs.

Microwave detection :   One Flash.
Microwave Masked  :   2.5 Flashes every second. 

 

 

Microwave 

Fault 

 

:   ON Dull (while Faulty).

Yellow LED Indications:

PIR Alarm 

:   ON for 3 secs.

PIR Alarm event 
(pulse count only) 

:   One Flash.

PIR Masked 

:   2.5 Flashes every second. 

 

PIR 

Fault

 

:   ON Dull (while Faulty)

9. Warranty

All Guardall products are warranted against defects in workmanship in 
materials (details available on request). In the interests of improving quality 
and design, Guardall reserve the right to amend specifi cations without giving 
prior notice. Faulty product should be returned to your supplier.

Note:

 Guardall recommend that the detector is regularly walk tested back to 

the control panel and that installers advise their customers to do this.

Отзывы: